7.3 Connecting
The operating voltage is supplied via the PLC/Power cable or the power plug.
Communication takes place via the PLC/Power cable and/or Ethernet, RS232.
7.3.1 Operating Voltage Supply
The operating voltage is supplied through the PLC/Power Cable (accessories)
or the power supply (accessories).
When using the power supply, the digital I/O interfaces of the device can not be
used.
Requirements on the operating voltage source
•
protective earth contact,
•
earthing.
Parameter
Parameter
Min
Nom
Max
Operating voltage
9 V
24 V
28 V
Current consumption at 24 V DC
125 mA
350 mA
Power consumption at 24 V DC
5.5 W
Table 10: Parameters of the operating voltage supply
ADVICE
The power supply of the camera and the power supply to the digital I/O
channels are separated internally.