background image

SLE-150-G530-P-SL

Scope of Delivery and Accessories

Connection cable DLC - operating voltage

Designation

Description

Order no.

Cable DLC3005 - 1.0 m

1-30-222

Cable DLC3005 - 2.0 m

to connect the DLC3005 to a current

source, PTSM 0.5/2-P-2.5 to cable

open end, 2x0.5 mm²

1-30-223

DLC Connector-Set

Designation

Description

Order no.

DLC3005 Connector-Set

(included in scope of

delivery)

3 connectors for connecting operating

voltage, I/O port and lighting (without

cable)

1 x PTSM 0.5/ 2-P-2.5

1 x PTSM 0.5/ 7-P-2.5

1 x PTSM 0.5/ 4-P-2.5

1-30-206

Connection cable DLC - PC

Designation

Description

Order no.

USB cable

Type-A/Micro-B - 1 m

(included in scope of

delivery)

to connect the DLC3005 to a PC,

USB 2.0 Type-A plug to micro-B plug

1-30-207

Connection cable M8-4-pin, straight plug, 4A, 60V

Designation

Description

Order no.

Connection cable

M8-4pin, 10m

Connection cable with 4-pin M8 socket

and open cable end with ferrules,

4 x 0.25 mm², 4A, 60V, PUR, IP67,

straight plug

1-11-607

12

999.995.381.10-en-1.3

© Vision & Control GmbH 2021

Summary of Contents for SLE-150-G530-P-SL

Page 1: ...CONTROL Instructions for Use SLE 150 G530 P SL Compact spot light Luminous colour Green 530 nm Instructions for Use SLE 150 G530 P SL Compact spot light Luminous colour Green 530 nm 999 995 381 10 en...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...on Description SLE Compact spot light Attachment optics with condenser lens High energy efficiency 150 Luminous field diameter in mm at 200 mm Working distance G530 Luminous colour Green 530 nm P Powe...

Page 4: ...Notices on the device 15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 17 5 3 Photometric Parameters 18 5 4 Conditions for Operation Storage and Transport 19 5 5 Technical Dr...

Page 5: ...SLE 150 G530 P SL Table of Contents 8 1 Maintenance 28 8 2 Service 29 9 Disposal 30 10 EU Declaration of Conformity 31 Vision Control GmbH 2021 999 995 381 10 en 1 3 5...

Page 6: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Page 7: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Page 8: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Page 9: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Page 10: ...ce and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric sh...

Page 11: ...x smart light lighting controller Designation Description Order no DLC 3005 Digital lighting controller wall mounting continuous operation 4 8 A flash operation 18 A 1 30 202 DLC 3005 R Digital lighti...

Page 12: ...operating voltage I O port and lighting without cable 1 x PTSM 0 5 2 P 2 5 1 x PTSM 0 5 7 P 2 5 1 x PTSM 0 5 4 P 2 5 1 30 206 Connection cable DLC PC Designation Description Order no USB cable Type A...

Page 13: ...pen cable end with ferrules 4 x 0 25 mm 4A 60V PUR IP67 angled plug 1 11 606 Connection cable M8 4 pin straight plug 5A 30V Designation Description Order no Connection cable M8 4pin 1m 1 11 611 Connec...

Page 14: ...ce Views 1 4 4 2 3 4 4 5 1 4 4 6 4 4 5 Image 1 Device view 1 Casing 2 Light emitting surface 3 Filter thread M28x0 5 depth 5 mm 4 Mounting hole M3x0 5 depth 4 5 mm 5 Mounting hole 4 2 through bore 6 C...

Page 15: ...ructions are provided on the device Made in Germany www vision control com SLX XXX XXXX P SL 2 1 4 3 1 Notes on power supply 2 Device designation as DataMatrix code 3 Device designation as plain text...

Page 16: ...on IP IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Continuous operation Risk group 0 exempt group Flash mode Risk group 1 Overheat protection TMAX 1 80 C 1 The LE...

Page 17: ...ters The LED overheating protection is not guaranteed Parameter Min Nom 1 Max Continuous operation LED current ILED 0 8 A Forward voltage ULED at ILED Max 3 4 V Power consumption Ptot 2 72 W Flash mod...

Page 18: ...36 nm Spectral bandwidth 33 nm Luminous efficacy of radiation 526 7 lm W Continuous operation Irradiance 1 9 W m2 Illuminance 1 4 563 lx Radiance 2 54 1 kW m2sr Luminance 2 28 5 Mcd m2 Flash mode Irra...

Page 19: ...e the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use Amb...

Page 20: ...2 3 4 5 1 2 3 4 5 A A B B C C D D 32 30 8 5 10 11 5 5 75 2 x M3 depth 4 5 mm on both sides 8 5 10 M8 connector 10 11 5 75 2 x M3 depth 4 5 mm 10 11 54 32 light emitting surface 26 mm M28x0 5 depth 4...

Page 21: ...energised state 6 1 Unpacking 1 Lift the cardboard together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion poc...

Page 22: ...the Device The following bores can be used for assembly 1 1 1 1 2 1 1 1 1 2 Image 4 Mounting holes 1 6 x M3x0 5 tapped hole maximum screwed in depth 4 5 mm 2 2 x 4 2 mounting hole through bore 22 999...

Page 23: ...disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lightin...

Page 24: ...ut 2 1 WH white BD Data Channel for vicolux smart light modules 3 BU blue ILED LED cathode negative current input 4 1 BK black BG Data Channel for vicolux smart light modules 1 Only use in conjunction...

Page 25: ...tective goggles If you have a known history of epilepsy do not work or stay in areas where there are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during...

Page 26: ...lux smart light lighting controller NOTICE Damage caused by incorrect connecting and disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights duri...

Page 27: ...es Continuous operation Apply a constant current ILED to the lighting Flash operation Apply current pulses ILED to the lighting Observe the specified parameters see Electrical Parameters page 17 Visio...

Page 28: ...e specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging it 1 Remove non adherent dusts with a blower...

Page 29: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Page 30: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Page 31: ...al environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Page 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Reviews: