24
CHAPTER 5: PART REPLACEMENT GUIDE
5.4 Generator Replacement – Continued
6) Loosen the nuts putting tension on the generator belt (Figure E). Then remove the eye bolt with plate (Figure F).
FIGURE E FIGURE F
7) Once the tension has been removed, the generator belt can be walked off of the secondary pulley (Figure G).
8) Pull the generator out of the frame towards the back of the unit and remove the generator belt (Figure H).
FIGURE G FIGURE H
9) Reverse Steps 1- 8 to install a new generator.
NOTE:
Re-tension the new generator belt to 90 ft / lbs of torque. The nuts removed in Step 5 should be
torqued to 40 N-m.
10) Test the Elliptical for function as outlined in Section 5.22.