Incline function does not work
Possible causes:
1.
The 8-pin console cable is damaged.
2.
Incline motor is damaged.
3.
PCB is damaged.
4.
MCB is damaged.
5.
The incline setting is not correct.
Fix:
u
Enter to P5 of Engineering Mode.
Then press "FAST" and "SLOW" key to see if the incline motor will be activated.
1.
OR
Use a new 8-pin console cable to connect PCB and MCB. Then press "FAST"
and "SLOW" key to see if the incline motor will be activated.
2.
OR
Replace the incline motor.
3.
OR
Replace PCB.
4.
OR
Replace MCB.
u
In the P5 of Engineering Mode.
Then press "FAST" and "SLOW" key to verify if the number in the (left) window
varies as the elevation changes.
u
OR
Ø
Replace 8-pin cable and check.
Ø
Replace incline motor and check.
Ø
Replace PCB and check.
5.
Enter Engineering Mode to reset the elevation parameter.