Error Message" E4" on the Console
Possible cause:
1.
Range of elevation is too short.
2.
PCB is damaged.
Fix:
1.
Enter the engineering mode to re-calibrate the elevation.
2.
Replace PCB.
Error Message " E5" on the Console
Possible cause:
1.
Range of elevation is not proper.
2.
PCB is damaged.
Fix:
1.
Enter the P4, P5 of Engineering
Mode1 to recalibrate the incline.
u
If the elevation is stuck at
either end, release the pipe before
the calibration.
2.
Replace PCB