 JUPITER PRO 1-3KVA   -   UPS    

www.visionups.com 

 

2.5.  Battery and charging

 

1.

 

When the UPS is connected to the mains, it recharges itself automatically.  The charger can charge the batteries up 
to 90% within 8 hours.

 

2.

 

Keep the batteries in full power condition so as to prolong their lifetime as well as their discharging time.  

 

3.

 

There are electronic and high voltage elements installed in the UPS – ensure that the appliance will be opened only 
by technically competent personnel because of the danger of electric shocks.  

 

4.

 

Respect, follow and use this manual with instructions. 

 

 
 
 
 

3. PRODUCT FEATURES 

 

3.1.  Wide input voltage range

 

The synchronous online technology for voltage regulation and with an operating input range of 165-275Vac (optional 150-
275Vac) requires a much rarer discharging and charging than usual and extends the effective usage time of the batteries. 

 
3.2.  Automatic switching function

 

! If you don’t need the auto-switch-function, turn off the input breaker on the rear of the device. 

 

Supply the UPS with mains and turn on the input breaker on the rear; the unit starts 15 seconds later to produce 
stabilized power for the load.  

 

 

The batteries supply power promptly when the mains is interrupted.  After finishing its discharge, the UPS is shutting 
off its long ringing automatically.  

 

 

The  UPS  restarts  automatically  when  the  main  power  has  recovered  after  the  interruption  and  recharges  the 
batteries as well.   

 

 

3.3.  User-specific alarm system 

 

The UPS starts its alarm (frequency once per 5 seconds) when the mains is off and the inverter begins to work.  The 
sound becomes automatically silent after 40 seconds in order to not disturb the working environment.  

 

The UPS starts automatically its long ringing (frequency 5 times per second) when the batteries are nearly exhausted 
in order to remind the persons that the batteries are used up and that the UPS will soon cut out.   

 

When the batteries are almost used up, the UPS shuts down automatically to protect the batteries. 

 

3.4.  Protective functions of the Online-UPS

 

 

Overload on main power condition: if the load amounts more than 110% on mains condition, the UPS sounds alarm 
during 60s.  Then it turns to bypass mode, at which the alarm tone stops as well.  Normal condition will be regained 
as soon as the load has decreased to a normal range again. 

 

Overload on normal inverter condition: if the load amounts more than 110% on inverter power condition, the UPS 
alarms with long ringing.   It will supply power again as soon as the load is decreased to a normal range within 60s.  
The acoustic signal will be terminated simultaneously.  Otherwise it shuts down itself automatically.  The user needs 
either to turn it on again manually by pressing the ON button, or has to wait for the recovering of main power.    

 

Overload on abnormal inverter condition: if the load amounts more than 125% on inverter power condition, the UPS 
alarms with long ringing.   The UPS cuts itself out after 5s.  The user needs either to turn it on again manually by 
pressing the ON button, or has to wait for the recovering of main power.   

 

Short-circuit protection on inverter power condition: if the output of the UPS meets transient crest current and short-
circuit strike, it will be limited in some degree if it’s over 10ms and the system shuts down automatically.  The user 
needs either to turn it on again manually by pressing the ON button, or has to wait for the recovering of main power.  
(If the system runs on mains, then the input fuse will melt at first protection.   Afterwards the UPS unit will switch 
over to inverter mode.). 
 

BATTERY

Filter

Transformer

Bypass

CHARGER

AVR

INVERTER

MAINS

Load

 

Summary of Contents for jupiter pro series

Page 1: ...User Manual Jupiter Pro series 1 3KVA Uninterruptible Power Supply ...

Page 2: ...achieve maximum lifetime of your UPS This manual explains the principle of inner operation and the corresponding protective functions It also contains information about the use of the equipment Please follow the given instructions and warning notices in this manual or on the unit itself Only operate the appliance after you have completely read and understood all the safety and operating instructio...

Page 3: ...nel 7 3 7 Automatic switch off in inverter mode when no load is available optional 7 3 8 Automatic distinction of the output frequency 7 3 9 Battery detection 7 3 10 Intelligent communication ports with intelligent PC assisted monitoring function optional 7 4 Technical specifications 8 5 Product components 9 5 1 Front panel 9 5 2 Back panel 9 6 Installation and operating 10 6 1 Installation of the...

Page 4: ...wall and UPS to avoid any overheating in areas free from flammable gas fume corrosive materials excessive dust conductive contaminants sparks strong vibrations to avoid damages in an interior room with controlled temperature the appliance is not suited for outdoor use no high or low temperatures above 40 C or below 0 C and or with high non condensing humidity above 90 for maintaining the battery l...

Page 5: ...ies are promptly supplying current to the inverter Then after passing through the wave filter the power can be sent to user s equipment without interruption 2 4 Power supply by bypass The bypass mode only happens in the following conditions 1 overload 2 UPS failure 3 Switch on keep pressing the ON button for 3 seconds the UPS will be in process of soft starting within 15 seconds 4 Switch off keep ...

Page 6: ...nging frequency 5 times per second when the batteries are nearly exhausted in order to remind the persons that the batteries are used up and that the UPS will soon cut out When the batteries are almost used up the UPS shuts down automatically to protect the batteries 3 4 Protective functions of the Online UPS Overload on main power condition if the load amounts more than 110 on mains condition the...

Page 7: ...ency 50Hz or 60Hz was before the mains collapsed 3 9 Battery detection The product can work with monitoring software to capture the battery at a certain time In the case of any error message such as an open circuit of battery cable or battery failure the unit can catch the error information through the communication ports to advise the user Meanwhile the UPS has a self protection function by shutt...

Page 8: ...t down within 5s Auto shut down with no load optional 5 shut down within 1min Short circuit System shuts down automatically Alarm AC abnormal Once per 4s silent after 40s Battery low Once per 0 2s Overload Once per 1s Battery DC voltage 24V 24V 36V 48V H 48V configuration standard UPS 2 x 12V7Ah 2 x 12V8Ah 3 x 12V8Ah 4 x 12V8Ah Recharge time 90 capacity after 8 hours Charging current long backup 1...

Page 9: ...when the UPS is working 4 UPS working condition indicator the green light is on when there is main power input the red light is on when there is no mains flowing 5 AC indicator orange the light is on when there is input main power 6 ON starting button start the UPS by pressing the button for 3 seconds The UPS produces output power normally within 15 seconds when starting daily 7 OFF shut down butt...

Page 10: ...n on the front panel for 3 seconds The UPS switches to bypass mode when the mains in on In this moment the bypass LED is illuminated otherwise the UPS shuts down its operating Precautions 1 When starting the computer take care of starting first the UPS and only after then the load of the computer And when switching off turn off first the computer and afterwards the UPS 2 Normally it s not necessar...

Page 11: ...utput power Then cut the main power supply off The UPS transfers automatically to battery mode before shutting down Take note of the discharging time in order to refer it later The total of the load current consumption is calculated in the unit Watt If the marking on the UPS just shows the power capacity in the unit VA then multiply the VA rating with the power factor PF 0 6 for calculating the ra...

Page 12: ...cannot work Whether the battery is not charged or the UPS is not switched on When power has failing computer stops to work Start the UPS when mains is normal Charge the battery during more than 10 hours and then start the UPS When the mains is connected the UPS beeps for 60 seconds and transfers then to bypass When no main power is entering the UPS shuts itself down automatically after 60 seconds ...