background image

12

EXAMPLE 4:  

To test the power supply and load on an IRS 
installation 

1.

 

Disconnect the EV5-034 power supply from the DC auxiliary 
input of the EV5 multiswitch. 

2.

 

Connect the power supply to the DC input (source) on the 
meter. 

3.

 

Check the voltage reads 18V. 

4.

 

Connect the TV/SAT Power Meter DC out (load) to the Auxiliary 
DC input of the multiswitch. 

5.

 

Press and hold the red “test” button. 

6.

 

Check the voltage remains at 18V when under load. 

7.

 

Add the current rating for each device on the system including 
all multiswitches, the LNB and any amplifier. 

8.

 

Check the current displayed matches the total system load 

9.

 

If the voltage under load is below 18V check the power supply is 
not faulty.  

10.

 

If the current displayed is significantly higher than the 
calculated current, check for faulty connections (whiskers of 
braid) and also for faulty equipment.  Use a process of 
illumination to check for faulty equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for V18-310

Page 1: ...V18 310 TV SATELLITE DC Power Tester...

Page 2: ...est the 12V supply to a masthead amplifier Page 5 Test the LNB input of a satellite receiver Page 7 Test the LNB input of IRS Page 9 Test the PSU and load on IRS installation Page 11 Test the voltage...

Page 3: ...llite systems connected to legacy satellite receivers SKY Sky HD Sky Q Freesat Freesat HD dSCR SCR and DiSEq installations etc IMPORTANT The V18 310 TV SAT Power Tester requires a PP3 6LR61 MN1604 9V...

Page 4: ...Do not use the product if you suspect it has been damaged in any way including being dropped is malfunctioning or has been exposed to liquids or moisture The unit must be repaired by an authorised ser...

Page 5: ...t move or carry the product by any other means other than the case as a whole or handle if provided This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must b...

Page 6: ...ead amplifier to the TV SAT Power Tester Load 5 Press the red test button Check the voltage and current display 6 If the voltage displayed is now lower than at step 4 or the current is higher than the...

Page 7: ...6...

Page 8: ...7...

Page 9: ...the voltage and current display 4 If the voltage displayed is now lower than at step3 or the current is higher than the equipment ratings label there is a fault in the installation Check the 22 KHz LE...

Page 10: ...9...

Page 11: ...t the TV SAT Power Tester DC OUT Load to the LNB feed marked H Lo green cable 4 Press the red test button Check the voltage and current display 5 If the voltage displayed is now lower than at point c...

Page 12: ...ss and hold the red test button 6 Check the voltage remains at 18V when under load 7 Add the current rating for each device on the system including all multiswitches the LNB and any amplifier 8 Check...

Page 13: ...12...

Page 14: ...13...

Page 15: ...TV SAT Power Meter to the H Lo terminal of the next piece of equipment in the trunk network to power the system 6 Press and hold the red test button 7 Read the current consumption of the system Does t...

Page 16: ...2017 Vision Products Europe Ltd Redbourne Park Brackmills Northampton NN4 7DT www vision products co uk technical vision products co uk 01604 664758...

Reviews: