background image

VZN H SERIES 

WATER FILTRATION 

VZN-441H, 1" NPT 

VZN-441H-T5, 1" NPT

Owner

s Manual

P/N 1011103 Rev. E 05/13

MANUFACTURING 

NUMBERS:

9700760 

9700765

System Tested and Certified by NSF 

International against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects 

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction

Turbidity Reduction.

Summary of Contents for VZN-441H

Page 1: ...Rev E 05 13 MANUFACTURING NUMBERS 9700760 9700765 System Tested and Certified by NSF International against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction ...

Page 2: ... 18 Check Permeate Tank Air Pre Charge 18 Troubleshooting 19 Replacement Parts 20 Notes 23 Limited Warranty 24 General The VZN system is an innovative filtration system that uses proprietary multi bore hollow fiber membranes as well as a carbon element to provide the latest innovation in filtration technology This manual provides the safety installation and operating procedures for the VZN water f...

Page 3: ...olumn and have it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the right to change specifications and product design without notice Such revisions do NOT entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment...

Page 4: ...All electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do NOT use an extension cord with this unit If the sup...

Page 5: ...leaning solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can cause irreversible damage to the mem brane All pipes must be flushed clean before installing the fil ter All plastic parts of the filter system must be protected from sharp objects like knives sand pap...

Page 6: ...100 240 10 08 50 60 VZN 441H T5 9700765 100 240 10 08 50 60 CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes A ground fault circuit interrupter GFCI must be installed on the circuit to this system When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes servi...

Page 7: ...laims for Percent Reduction NOTE The NSF information provided applies to the Ultra Filter cartridge Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain fil terable cysts Filter Cartridge Capacities Maximum Operating Pressure 100 p...

Page 8: ... wall The Drain Valve is only powered during Flush Mode NOTE Do NOT unplug the power cord or turn off the sys tem during Flush Mode If there is a power outage or the system is unplugged water will continue to be filtered but the system will NOT flush This could cause the Ultra Filter to plug prematurely and may reduce the life of the filter The flush is automated by the Universal Pulse Controller ...

Page 9: ...t Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 1 NPT System Outlet Product Water 1 NPT Drain 3 4 FNPT Rinse Outlet 3 4 GHT Garden Hose It is recommended that ball valves be installed on the inlet and outlet of the ...

Page 10: ...ottom mount ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and level to attach the Mounting Bracket securely to the wall with the appropriate mounting hardware Figure 2 2 The Mounting Bracket is designed so that the VZN system can be lifted and hung on the Mounting Bracket With assis...

Page 11: ...is flow rate is dependent on the inlet water pressure inlet pipe size and system The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 4 This air gap protects the system from contamination in the event of a backed up drain The drain used mus...

Page 12: ...il all debris is removed Filtered Water Permeate Outlet Connection The System Outlet has a 1 NPT male thread Figure 6 It is recommended that a 1 ball valve be installed at the System Outlet Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections 3 4 Garden Hose Connection...

Page 13: ...nutes open the Rinse Ball Valve and wait for five minutes to flush out any remaining air 12 Close the Rinse Ball Valve and disconnect the garden hose 13 Press the FLUSH button to open the Drain Valve Repeat six times to ensure any remaining air is flushed out of the system 14 Open the closest downstream tap or faucet 15 Slowly open the Outlet Ball Valve and allow water to run through the system an...

Page 14: ... open the Inlet Valve c Allow the pipe to flush until all debris is removed Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contam ination that may have occurred during the installation process One ounce 30 ml of liquid chlorine bleach regular bleach unscented 5 25 6 sodium hypochlorite or Kay 5 sanitizer solution Sodium Dichloro s Triazinetrione Dihydrate 6 or...

Page 15: ...ight coating of lubricant to the inside center tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 11 Install the End Cap O ring on the End Cap and insert the Large End Cap into the end of the new cartridge 12 Position the new cartridge and End Cap at the housing and gentl...

Page 16: ...containing the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a drain NOTE It is important to direct the System Outlet to the drain as the water resulting from the flush should NOT be used 11 Ensure the ...

Page 17: ...e end of the thread Use a Filter Wrench if necessary 10 Direct the water from the Rinse Ball Valve to a drain NOTE It is important to direct the system outlet to drain as the water resulting from the flush should NOT be used 11 Slowly turn on the water to the system and allow water to flow through the TAC Cartridge and Housing to clear out trapped air and any carbon fines that may be pres ent 12 T...

Page 18: ...n cause the Ultra Filter to plug prematurely and may reduce the life of the filter Consult the factory for more information CAUTION Air pre charge should only be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre charge Do NOT adjust the tank air pre charge with the system under pressure CAUTION Be careful when adding air to the tank Do NO...

Page 19: ...defective Clean or replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water co...

Page 20: ...VZN H SERIES 20 P N 1011103 Rev E 05 13 REPLACEMENT PARTS VZN 441H Systems 30 33 25 1 2 37 3 31 34 12 28 20 14 35 29 16 32 15 36 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 9 8 10 10 ...

Page 21: ...RIES 21 P N 1011103 Rev E 05 13 REPLACEMENT PARTS continued VZN 441H T5 Systems 30 33 25 1 2 40 3 31 34 12 20 16 32 15 39 19 4 5 6 7 8 9 11 17 21 13 18 20 21 22 23 24 9 8 10 10 36 37 25 28 14 29 26 27 24 35 38 ...

Page 22: ... 1 Stem 1 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 2190167 Adapter 3 4 Garden Hose 1 39 0021666 Flow Regulator Assy 15 gpm 1 40 0021666 Power Adaptor 1 41 2190184 Tee PVC 3 4 NPT not shown 1 42 2190135 Plug Nylon 3 4 NPT not shown 1 VZN 441H Systems Item Part Description Qty No Item Part Description Qty No 1 0505870 VZN Back Plate 1 2 0012357 Universal Pulse Cont...

Page 23: ...VZN H SERIES 23 P N 1011103 Rev E 05 13 NOTES ...

Page 24: ... operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a w...

Reviews: