Introduction 

 

Thanks for choosing the Vision’s Power Monitor or On/Off Module of the home automation device. This 
Power  Monitor  or  On/Off  Module  is  a  Z-Wave

  TM

  enabled  device  (interoperable,  two-way  RF  mesh 

networking technology) and is fully compatible with any Z-Wave

 TM

 enabled network. Every main powered 

Z-Wave

  TM 

enabled  device  acts  as  a  signal  repeater  and  multiple  devices  result  in  more  possible 

transmission routes, which helps eliminate “RF dead-sport”. 
Z-Wave

  TM

  enabled  devices  displaying  the  Z-Wave

 TM

  logo  can  also  be  used  with  it  regardless  of  the 

manufacturer,  and  ours can  also be  used  in  other manufacturer’s Z-Wave

 TM

  enabled  networks.    This 

module  will  send  On/Off  signal  to  the  appliance  that  attached  to  this  module  by  receiving  Z-Wave

 TM

 

signal from controller or manually switch.    It also sends the energy consumption (ZL7261 only) to the 
controller when it requests.    With special design, this module won’t interfere the other power outlet when 
plug into the AC outlet.    This module also acts as repeater (supporting FLiRS).

 

Product Description and Specification 

 

 

 

 

     

 

 

Specification: 

Package Content: 

Protocol: Z-Wave

 TM

 (ZM5202) 

Frequency: 
        868.42 MHz (ZL7201CN/DE/FR/IT / ZL7261CN/DE/FR/IT) 
        869.00 MHz (ZL7201RU / ZL7261RU) 
        908.40 MHz (ZL7201CL/US / ZL7261CL/US) 
        919.70 MHz (ZL7201KR / ZL7261KR) 
        922-926MHz (ZL7201JP / ZL7261JP) 
Operating Temp. -15

°

C~ 60

°

C (-5

°

F~ 140

°

F) 

Operating Voltage: AC 100V~230V 
Operating Range: Up to 100 feet (about 30m) 
Data Rate: Up to 9.6k/40k/100kbps 
Application: Indoor use 
Max Loading 

1pc 

Power Monitor or On/Off Module 

1pc User Manual

 

    Type B: 110V/15A/1600W (Resistive) 
                    220V15A/3200W (Resistive) 
    Type E, F & L: 230V/10A/2300W (Resistive)     

 

Z-Wave

  Command Class: 

   

 

COMMAND_CLASS_APPLICATION_STATUS 
COMMAND_CLASS_ASSOCIATION_GRP_INFO 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_CONFIGURATION 
COMMAND_CLASS_DEVICE_RESET_LOCALLY 
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 

      COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
      COMMAND_CLASS_METER_V4 (ZL7261 only) 

COMMAND_CLASS_POWERLEVEL 
COMMAND_CLASS_PROTECTION (ZL7201 only) 
COMMAND_CLASS_SECURITY 
COMMAND_CLASS_SWITCH_ALL 
COMMAND_CLASS_SWITCH_BINARY mapping COMMAND-CLASS_BASIC 

      COMMAND_CLASS_VERSION_V2 
      COMMAND_CLASS_ZWAVEPLUS_INFO 
 

 

Operation 

 

If  you  are  installing  the  entire  Z-Wave

  TM

  system  for  the  first  time,  please  refer  to  the 

installation guide of Z-Wave

 TM

 Interface Controller before installing 

ZL7261 or ZL7201.

 

 

1. 

For  “

Inclusion

”  in  (adding  to)  a  network:  Put  the  Z-Wave

  TM

  Interface  Controller  into 

“inclusion”  mode,  and  following  its  instruction  to  add  the 

ZL7261  or  ZL7201 

into  your 

controller.    To get in the “Inclusion” mode, the distance between

 ZL7261 or ZL7201

 and 

controller is suggested to be in one meter. By power up to get included for first time, or 
press the Program switch 

3 times within 2 seconds to be included. 

For  “

Exclusion

”  from  (removing  from)  a  network:  Set  up  the  Z-Wave

  TM

  Interface 

Controller  into  “exclusion”  mode,  and  following  its  instruction  to  delete  the 

ZL7261  or 

ZL7201

 from your controller.    Press the Program Switch

 3 times within 2 seconds to 

be excluded. 
 

For “Association”: the Z-Wave

 TM

 interface controller set “Association”, and following its 

instruction to associate the 

ZL7261 or ZL7201 

with other device. Support one group (5 

nodes). 

ZL7261 or

 

ZL7201 

will report back every time ON and OFF status, also it will 

reports every notification to all devices in the association group. 
 

2.  For “Meter Supported Get” (ZL7261 only): the Z-Wave

 TM

 Interface Controller or Gateway 

can  send  “Meter  Get”  command  with  any  of  the  following  supported  scales,  and  the 
ZL7261 will report back with the energy consumption values for the requested scale: 

Scale: 0x00-kWh(Default); 
            0x01-kVAh 
            0x02-W 
            0X04-V 
            0X05-A   
            0X06-Power Factor. 
 

 