Introduction
Thanks for choosing the Vision
’s wireless smoke detector
of the home security device.
This detector is a Z-Wave
™ enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any Z-Wave
™ enabled network.
Every mains powered Z-Wave
™
enabled device acts as a signal repeater and multiple
devices result in more possible transmission routes which helps eliminate
“RF
dead-sports
”.
Z-Wave
™
enabled devices displaying the Z-Wave
™
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer
’s
Z-Wave
™
enabled networks. This detector is designed to sense smoke that comes into
the detector chamber and send Z-Wave
™
signal when the detector detects a certain
density of smoke then the horn of smoke detector will sound.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave
™ (ZS6101N)
Frequency Range:
868.42MHz (ZS6101EU)
908.42MHz (ZS6101US)
921.42MHz (ZS6101AU)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10
°C
~ 50
°C
(14
°F
~122
°F
)
Battery: Panasonic CR123A * 1PC
1pc
1pc
1pc
2pcs
1pc
1pc
1pc
ZS 6101 Smoke
Detector
Bracket Holder
Plastic Anchor &
Screw
CR123ALithium
Battery
Installation &
Operation Manual
Installation
Notice: If you are installing the entire Z-
Wave™ system for the first time, please refer to
the installation guide of Z-
Wave™ Interface Controller before installing ZS6101.
1.
Remove the bracket from the detector by rotating it counter-clockwise.
2.
Place the bracket where you are going to install the detector. In each of key hole
slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill
bit, drills two holes at the marks and insert plastic anchor, and attached the bracket
by using the screws.
3.
Open the battery cover to insert the battery, and then replace the cover. Fix the
detector with bracket by rotating it clockwise.
4.
For
“Inclusion”
in (adding to) a network: Put the Z-Wave
™ Interface Controller into
“inclusion” mode, and following its instruction to add the ZS 6101 to your controller.
To get in the
“inclusion” mode, the distance between detector and controller is
suggested to be in one meter. Press the program switch of ZS 6101 for 1 second at
least to be included.
For
“Exclusion”
from (removing from) a net work: Put the Z-Wave
™ Interface
Controller into
“exclusion” mode, and following its instruction to delete the ZS 6101
from your controller. Press the program switch of ZS6101 for 1 second at least to be
excluded.
Please note: LED setting light will flash (red) continuously in Exclusion condition.
For
“Awake”
mode: it is to leave the
“Sleep” mode by pressing the program switch
for 1 sec. at least to allow the Z-Wave
™ Interface Controller to do “Inclusion”,
“Exclusion”, “Association” and to reply and receive the commands from controller. It
will take about 5 sec. and the red LED light on for awaking the system. LED light will
be off after setting.
For
“Association”
: After
“Awake” mode, then put the Z-Wave
™
Interface
Controller into
“Association”, and following its instruction to associate the ZS6101
with other device. Afterward the ZS6101 will get into
“Sleep” mode for power saving.
One association group supports 5 nodes.
For
“
Auto Wake-up
” mode: The user’s could set Auto Wake-Up mode in min. 10
minutes to max. a week. Default setting is based on 1 hour, each increment in 200
sec.
5.
Suggestion of the Smoke Detector Location:
-2-
-1-