Operation 

 

1. 

Power-on Mode: 

1) Install the battery into the module 2) Close the bracket   

3) the detector will take 8 to 12 sec. and emit a beep to confirm and start the burglar 
system. The detector will alarm once remove the bracket.     

2. 

Stand-by Mode:

 The Red LED flashs one time every 11 seconds. 

3. 

Alarm Mode (It

’s the status when the alarm is triggered.):

 If a certain density of 

smoke is detected, an audible alarm with 3 beeps, pause and 3 beeps will occure. 
The red LED will flash continuously and rapidly. Meanwhile, the smoke detector will 
send an alarm sensor report (type: smoke alarm, state: alarm) to the user

’s 

controller and also the dectecor will send an alarm sensor report (type: smoke 
alarm, state: No alarm) while the alarm off. 

4. 

Error Mode:

 If the smoke detector beep and yellow LED flash three tmes, it 

indicates the smoke detector is not working properly. Please requir to repaire or 
service.   

5. 

Low battery warning Mode:

 The yellow LED will flash once every 43 senods with 

a short 

“beep” sound. 

6. 

Testing Mode: 

Test the alarm weekly by pushing test switch

 

for about 3 sec.

 

until 

the user hear 3 beeps and red LED light on contuniously. Then, the smoke detector 
will send an alarm sensor report (type: smoke alarm, state: alarm) to the user

’s 

controller and also the dectecor will send an alar m sensor report (type: smoke 
alarm, state: No alarm) while the alarm off. Please note if the detector only beep 
once and red LED falsh three times, it indicates the detector is not working properly. 
Please require to repair or service.

         

 

7. 

Battery Power indicator:

 The detector will report the current status of battery 

capcity to the user

’s contorller. 

8. 

Self-Protection Mode: 

If the detector removed from bracket after 8 sec, the 

detector will send an alarm report (type:0*02, level:0*FF) to the Z-Wave Interface 
Controller , and the Yellow LED will on contiuously and the detector will sound.  

9. 

Silence Mode: 

The user could press the test switch to get into silence mode to turn 

off the alarm temporarily when the detector alarm. The silence function will 
automatically turn into normal operation if the smoke concentration around the 
detector is still at alarming level after 10 minutes of silence mode. 

 
 
 
 

    Federal Communications Commission Statement 

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instruction, may 
cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try and correct the interferene by one of the following measures: 
-- Reorient or relocate the receiving antenna, 
-- Increase the separation between the equipment and receiver, 
-- Connect the equipment into and outlet on a circuit different from that to which the receiver is 
connected. 
-- Consult the dealer or an experienced radio/TV technician for help. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undersired operation. 
FCC Caution: Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user

’s authority to operate this equipment

 

Limited Warranty 

 

Vision Guarantees that every wireless smoke detector is free from physical defects in 
material and workmanship under normal use for one year from the date of purchase. If 
the product proves defective during this one-year warranty period, Vision will replace it 
free of charge. Vision does not issue any refunds. This warranty is extended to the 
original end user purchase only and is not transferable. This warranty does not apply to: 
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent 
use; (2) units which have been subject to unauthorized repair, opened, taken apart, or 
otherwise modified; (3) units not used in accordance with instruction; (4) damages 
exceeding the cost of the product; (5) transit damage, initial installation costs, removal 
cost, or reinstallation cost. 
For information on addional devices, plesae visit us at www.visionsecurity.com.tw 

 

 

 

 

 

 

 

 

 

 

Install second-floor alarms at the top of first-to-second floor stairwell. 
Install basement alarms at the bottom of the basement stairwell. 

 