Wiegand Mode 

Pass through mode (VIS-3009 operating as a Wiegand Output Reader) 

In this mode the VIS-3009 supports a Wiegand 26~37bit output so the Wiegand data lines can be connected to 

any  controller  which  supports  a  Wiegand  26~37  bit  input,  and  then  the  VIS-3009  will  be  operated  as  a  slave 

reader. 

 

 

Transmission Format: 

● Card Transmission 

The Reader will transmit the card number (the 10 digits number on the card) when it reads the Card 

 

- Controller Mode (VIS-3009 operating as a Controller)

 

VIS-3009 supports a Wiegand 26~37 bit input so an external Wiegand device with a 26~37 bit output can be 

connected to the Wiegand input terminals on the VIS-3009. Either an ID card reader (125 KHz) or an IC card 

reader (13.56MHz) can be connected to the VIS-3009. Cards are required to be added at the external reader, 

except where an external EM reader is used, in this case cards can be added at either reader or controller.   

 

Summary of Contents for VIS-3009

Page 1: ...Access Control Black Outdoor IP66 Weatherproof Card Reader Standalone No Software Wiegand 26 37 Bits 125KHz EM Cards 1 000 Users VIS 3009 User Manual...

Page 2: ...ed With Wiegand 26 37 input output Pulse mode Latch mode Card block enrolment Tri colour LED status display Built in light dependent resistor LDR for anti tamper Integrated Alarm Buzzer Output Low tem...

Page 3: ...Drill 2 holes A C on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes A C Fix the back cover firmly on the wall with 4 flat head screws Thread the...

Page 4: ...rple Relay Common Common Connection for Relay Output Orange Relay NC Normally Closed Relay Output Install diode provided Yellow OPEN Request to Exit REX Input Pass Through Wiring Wiegand Reader Green...

Page 5: ...AC Power Supply Attention Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004 is included in the packing Access Control Power Supply...

Page 6: ...d Any 125KHz industry standard 26 bit EM Proximity card Enter and Exit Program mode Set Master Code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Update Master Code 0 New M...

Page 7: ...ode 2 Delete User By User ID OR 2 Delete User By Card OR 2 Delete User By Card number OR 2 Delete All User 2 User ID 2 Read Card 2 Input 8 10 digits Card number 2 Mater Code 3 Exit Set Relay Configura...

Page 8: ...Keystroke Combination 1 Enter Program Mode Master Code 2 Control Sounds OR 2 Control LED OFF 7 0 OFF 7 4 ON 7 1 ON 7 5 Factory defaults are ON 3 Exit Users Operation Open the door Read the valid user...

Page 9: ...Code 2 Interlocked OFF OR 2 Interlocked ON 9 0 Factory default 9 1 3 Exit Connection diagram see picture Interlock at page 13 Set Card Reading Type Programming Step Keystroke Combination 1 Enter Progr...

Page 10: ...transmit the card number the 10 digits number on the card when it reads the Card Controller Mode VIS 3009 operating as a Controller VIS 3009 supports a Wiegand 26 37 bit input so an external Wiegand...

Page 11: ...oad download 1000 users in 3 minutes Method For example Device A Master code is 222222 with User data Device B Master code MUST be 123456 without User 1 Make connection D0 A connect D0 B D1 A connect...

Page 12: ...ming mode 123456 then you can do the programming 123456 is the default factory master code change the master code 0 new code repeat the new code code 6 digits Add card user 1 Read Card can add Cards c...