background image

INTRODUCTION   

The VIS-3009 is single door multifunction standalone access controller or a Wiegand output card reader. It uses 

Atmel microcontroller assures maximum performance in any environment, and the low-power circuit makes its 

service life prolonged.   

 

The VIS-3009 supports 1,000 users (998 common users + 2 panic users), all user data can be downloaded and 

uploaded. It has extra features including block enrollment, interlocked, 

Wiegand 26~37 bits interface…etc.   

 

Features 

 

Waterproof, conform to IP66 

 

One relay, Remote infrared programmer 

 

1,000 users (998 common users + 2 panic users) 

 

User data can be downloaded and uploaded 

 

With Wiegand 26~37 input & output 

 

Pulse mode, Latch mode

 

 

Card block enrolment 

 

Tri-colour LED status display 

 

Built in light dependent resistor (LDR) for anti tamper 

 

Integrated Alarm Buzzer & Output 

 

Low temperature resistance (-40°C) 

 

Specifications: 

User Capacity   

Common User 

Panic User 

1000 

998 

Operating Voltage   

Idle Current 

12~24V AC/DC 

35mA   

Proximity Card Reader 

Radio Technology   

Read Range 

EM 

125KHz Proximity Card 

2~6 cm (0.78~2.36 in.) 

Wiring Connections   

Relay Output, Exit Button 

Relay 

Adjustable Relay Output Time 

Lock Output Load 

One (NO, NC, Common) 

1-99 Seconds (5 seconds default) 

2 Amp Maximum 

Environment 

Operating Temperature 

Operating Humidity   

Meets IP66 

-40°C ~60°C (-40°F ~ 140°F) 

0%RH-98%RH 

Physical 

Colour 

Dimensions 

Unit Weight   

Shipping Weight 

ABS Shell 

Black 

102L x 48W x 20H (mm) 

– 4.01L x 1.88W x 0.78 (in.) 

125g 

150g   

Summary of Contents for VIS-3009

Page 1: ...Access Control Black Outdoor IP66 Weatherproof Card Reader Standalone No Software Wiegand 26 37 Bits 125KHz EM Cards 1 000 Users VIS 3009 User Manual...

Page 2: ...ed With Wiegand 26 37 input output Pulse mode Latch mode Card block enrolment Tri colour LED status display Built in light dependent resistor LDR for anti tamper Integrated Alarm Buzzer Output Low tem...

Page 3: ...Drill 2 holes A C on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes A C Fix the back cover firmly on the wall with 4 flat head screws Thread the...

Page 4: ...rple Relay Common Common Connection for Relay Output Orange Relay NC Normally Closed Relay Output Install diode provided Yellow OPEN Request to Exit REX Input Pass Through Wiring Wiegand Reader Green...

Page 5: ...AC Power Supply Attention Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004 is included in the packing Access Control Power Supply...

Page 6: ...d Any 125KHz industry standard 26 bit EM Proximity card Enter and Exit Program mode Set Master Code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Update Master Code 0 New M...

Page 7: ...ode 2 Delete User By User ID OR 2 Delete User By Card OR 2 Delete User By Card number OR 2 Delete All User 2 User ID 2 Read Card 2 Input 8 10 digits Card number 2 Mater Code 3 Exit Set Relay Configura...

Page 8: ...Keystroke Combination 1 Enter Program Mode Master Code 2 Control Sounds OR 2 Control LED OFF 7 0 OFF 7 4 ON 7 1 ON 7 5 Factory defaults are ON 3 Exit Users Operation Open the door Read the valid user...

Page 9: ...Code 2 Interlocked OFF OR 2 Interlocked ON 9 0 Factory default 9 1 3 Exit Connection diagram see picture Interlock at page 13 Set Card Reading Type Programming Step Keystroke Combination 1 Enter Progr...

Page 10: ...transmit the card number the 10 digits number on the card when it reads the Card Controller Mode VIS 3009 operating as a Controller VIS 3009 supports a Wiegand 26 37 bit input so an external Wiegand...

Page 11: ...oad download 1000 users in 3 minutes Method For example Device A Master code is 222222 with User data Device B Master code MUST be 123456 without User 1 Make connection D0 A connect D0 B D1 A connect...

Page 12: ...ming mode 123456 then you can do the programming 123456 is the default factory master code change the master code 0 new code repeat the new code code 6 digits Add card user 1 Read Card can add Cards c...

Reviews: