background image

 

Preventive and Cautionary Tips 

 

Before connecting and operating your device, please be advised of the following tips:  

 

Ensure unit is installed in a well-ventilated, dust-free environment.  

 

Keep all liquids away from the device.  

 

Ensure environmental conditions meet factory specifications.  

 

Ensure unit is properly secured to a rack or shelf. Major shocks or jolts to the unit as a result of 
dropping it may cause damage to the sensitive electronics within the unit.  

 

Use the device in conjunction with an UPS if possible.  

 

Power down the unit before connecting and disconnecting accessories and peripherals.  

 

A factory recommended HDD should be used for this device.  

 

Improper use or replacement of the battery may result in hazard of explosion. Replace with the 
same or equivalent type only. Dispose of used batteries according to the instructions provided 
by the manufacturer.  

Safety Information 

Signs

 

Description

 

  Warning

 

Follow these safeguards to prevent serious 

injury or death. 

  Note

 

Follow these precautions to prevent potential 

injury or material damage. 

  Tips

 

The additional information as a complimentary 

of the contents. 

 

  Warnings 

Please  adopt  the  power  adapter  from  the  legitimate  factory  which  can  meet  the  safety  extra  low 
voltage (SELV) standard. 
Do not install, wiring, or uninstall when the power is still on. 
To reduce the risk of fire or electrical shock, do not expose this product to rain or moisture. 
This installation  should  be made by a qualified service person and  should  conform  to all the local 
codes. 
If the product does not work properly, please contact your dealer or the nearest service center. Never 
attempt to disassemble the product yourself. (We shall not assume any responsibility for problems 
caused by unauthorized repair or maintenance.) 

  Note 

Please do not drop  the  objects on  hard surface, and keep  the equipment from the magnetic field. 
Avoid install the equipment to the vibrated or vulnerable places. 
Please do not install the device in the extreme temperature (higher than 65°C or lower than -20°C) 
Keep ventilation. 
Do not operate in humid environment. 
Do not operate in explosive environment. 
Keep the device clean and dry. 
Avoid bare electrical wire. 

Summary of Contents for VS-AXESS-2D-ETL-PCB

Page 1: ...1 Two Door Access Controller Panel Board TCP IP Wiegand with Software and Power Supply Included 10 000 Users VS AXESS 2D ETL PCB Installation Manual...

Page 2: ...r TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS WITH ALL FAULTS AND ERRORS AND VISIONIS MAKES NO WARRANTIES EXPRESS...

Page 3: ...undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards liste...

Page 4: ...ow these precautions to prevent potential injury or material damage Tips The additional information as a complimentary of the contents Warnings Please adopt the power adapter from the legitimate facto...

Page 5: ...on of Cathode Lock 12 4 2 2 Installation of Anode Lock 13 4 3 CONNECTING THE EXTERNAL ALARM DEVICE 13 4 4 DOOR BUTTON WIRING DIAGRAM 14 4 5 THE CONNECTION OF MAGNETICS DETECTION 14 4 6 CONNECTING POWE...

Page 6: ...store 10 thousand legal cards and 50 thousand card swiping records Supports first card open function super card and super password function online upgrade function and remote control of the doors Supp...

Page 7: ...7...

Page 8: ...8 Chapter 2 Appearance 2 1 Component Description Access Controller Component Schematic Diagram The component schematic diagram is shown below Figure 2 1 VS AXESS 4D ETL PCB Component Schematic Diagram...

Page 9: ...Description No Component Description VS AXESS 2D ETL PCB 1 Door Lock 1 2 Indicator 2 Power Indicator 3 Network Indicator 4 Jumper Cap for Restoring Factory Settings 5 Working Indicator 6 Alarm Output...

Page 10: ...l Description Table 3 1 VS AXESS 2D ETL PCB Terminal Description No VS AXESS 2D ETL PCB A1 Alarm Input IN2 Alarm Input 2 A2 GND Grounding A3 IN1 Alarm Input 1 B1 Door 2 NC Door Lock Relay Output Dry C...

Page 11: ...ard Reader Power Output C7 GND C8 Wiegand Card Reader 2 OK Indicator of Card Reader Control Output Valid Card Output C9 ERR Indicator of Card Reader Control Output Invalid Card Output C10 BZ Card Read...

Page 12: ...pen door relay output For single door access controller the Wiegand card reader 1 and 2respectivelycorrespond to the entering and exiting card readers of door 1 For two door access controller the Wieg...

Page 13: ...must connect the OK ERR BZ if using access controller to control the LED and buzzer of the Wiegand card reader 4 2 Installing Door Lock 4 2 1 Installation of Cathode Lock Figure 4 2 Wiring diagram of...

Page 14: ...14 4 2 2 Installation of Anode Lock Figure 4 3 Wiring diagram of anode lock 4 3 Connecting the External Alarm Device Figure 4 4 External Alarm Device Connection...

Page 15: ...15 4 4 Door Button Wiring Diagram Figure 4 5 Power Button Connection 4 5 The Connection of Magnetics Detection Figure 4 6 Magnetics Connection...

Page 16: ...dware Steps 1 The jumper cap jumps from Normal to Initial 2 Disconnect the power and restart the access controller the controller buzzer buzzes a long warning 3 After the buzzer stops jump the jumper...

Page 17: ...the parameters to the default setting and all the device events are wiping out 5 2 Relay Input NO NC 5 2 1 Lock Relay Output Lock Relay Normally Open Status Figure 5 2 Normally Open Status Lock Relay...

Page 18: ...ormally Open Figure 5 4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5 5 Normally Closed Status Work Flow of Software For detailed information please see the user manual...

Page 19: ...19 Figure 6 1 Software Client Work Flow...

Page 20: ...r detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the official website and install the SADP according to the prompts Follow...

Page 21: ...heckbox of Enable DHCP 6 Input the password and click the Save button to activate your IP address modification STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own...

Page 22: ...l the software according to the prompts Follow the steps to activate the control panel Steps 1 Run the client software and the control panel of the software pops up as shown in the figure below 2 Clic...

Page 23: ...ton to start activation STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own choosing using a minimum of 8 characters including upper case letters lower case letter...

Page 24: ...p up the Network Parameter Modification interface 9 Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DH...

Reviews: