26
7. Click
OK
button to start activation.
8. Click the
button to pop up the Network Parameter Modification interface.
9. Change the device IP address to the same subnet with your computer by either modifying the IP
address manually or checking the checkbox of Enable DHCP.
10. Input the password to activate your IP address modification.
Specification
Model
VS-AXESS-4DLX
Power
DC 12V/1A
Processor
32bit
Capacity
16M
Uplink Communication Interface
TCP/IP Interface, and RS-485 Interface
Downlink Communication Interface
RS-485 and Wiegand
Normal Card/Event Log
100,000 normal card and 300,000 card wiping logs
LED Indicators
Power Status, Communication Status, Exception Status
Embedded Timer
Yes
Card Readers
8* RS485 Card Reader and 4* Wiegand Card Reader
Input Port
Alarm Input*4, Door Contact *4, Door Button*4, Case
Input*8, Anti-Tamper*1
Output Port
Door Relay * 4, Alarm Relay * 4
Working Temperature
-20°C -- +65°C
Working Humidity
10%--90% (noncondensing)
Dimension
370mm(L)*345mm(w)*90mm(H)
Table 6-1 VS-AXESS-4DLX Specification