background image

18 

 

  Note: 

The initializing of the hardware will restore all the parameters to the default setting and all the 
device events are wiping out. 

 

5.2 Relay Input NO/NC 

 
5.2.1  Lock Relay Output 

Lock Relay Normally Open Status 

 

Figure 5-2 Normally Open Status 

 

 

Lock Relay Normally Closed Status 

 

Figure 5-3 Normally Closed Status 

 

 
 
 
 
 

Summary of Contents for VS-AXESS-4D-ETL-PCB

Page 1: ...1 Four Door Access Controller Panel Board TCP IP Wiegand with Software and Power Supply Included 10 000 Users VS AXESS 4D ETL PCB Installation Manual...

Page 2: ...r TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS WITH ALL FAULTS AND ERRORS AND VISIONIS MAKES NO WARRANTIES EXPRESS...

Page 3: ...undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards liste...

Page 4: ...ow these precautions to prevent potential injury or material damage Tips The additional information as a complimentary of the contents Warnings Please adopt the power adapter from the legitimate facto...

Page 5: ...on of Cathode Lock 13 4 2 2 Installation of Anode Lock 14 4 3 CONNECTING THE EXTERNAL ALARM DEVICE 14 4 4 DOOR BUTTON WIRING DIAGRAM 15 4 5 THE CONNECTION OF MAGNETICS DETECTION 15 4 6 CONNECTING POWE...

Page 6: ...store 10 thousand legal cards and 50 thousand card swiping records Supports first card open function super card and super password function online upgrade function and remote control of the doors Supp...

Page 7: ...7...

Page 8: ...8 Chapter 2 Appearance 2 1 Component Description Access Controller Component Schematic Diagram The component schematic diagram is shown below Figure 2 1 VS AXESS 4D ETL PCB Component Schematic Diagram...

Page 9: ...scription No Component Description VS AXESS 4D ETL PCB 1 Door Lock 1 2 3 4 Indicator 2 Power Indicator 3 Network Indicator 4 Jumper Cap for Restoring Factory Settings 5 Working Indicator 6 Alarm Outpu...

Page 10: ...PCB Terminal Description Table 3 1 VS AXESS 4D ETL PCB Terminal Description No VS AXESS 4D ETL PCB A1 Alarm Input IN4 Alarm Input 4 A2 GND Grounding A3 IN3 Alarm Input 3 A4 IN2 Alarm Input 2 A5 GND G...

Page 11: ...r Button Input A29 GND Grounding A30 SENSOR Door Magnetic detector B1 Wiegand Card Reader 1 OK Indicator of Card Reader Control Output Valid Card Output B2 ERR Indicator of Card Reader Control Output...

Page 12: ...PWR Card Reader Power Output B28 GND C1 Power GND DC12V Grounding C2 12V DC12V Input D1 Alarm Output 4 COM4 Alarm Relay Output 4 Dry Contact D2 NO NC4 D3 Alarm Output 3 COM3 Alarm Relay Output 3 Dry...

Page 13: ...cess controller the Wiegand card reader 1 2 3 and 4 respectively correspond to the entering card readers of door 1 2 3 and 4 Chapter 4 External Device Wiring 4 1 Card Reader Wiring Figure 4 1 Wiring d...

Page 14: ...14 4 2 Installing Door Lock 4 2 1 Installation of Cathode Lock Figure 4 2 Wiring diagram of cathode lock...

Page 15: ...15 4 2 2 Installation of Anode Lock Figure 4 3 Wiring diagram of anode lock 4 3 Connecting the External Alarm Device Figure 4 4 External Alarm Device Connection...

Page 16: ...16 4 4 Door Button Wiring Diagram Figure 4 5 Power Button Connection 4 5 The Connection of Magnetics Detection Figure 4 6 Magnetics Connection...

Page 17: ...dware Steps 1 The jumper cap jumps from Normal to Initial 2 Disconnect the power and restart the access controller the controller buzzer buzzes a long warning 3 After the buzzer stops jump the jumper...

Page 18: ...the parameters to the default setting and all the device events are wiping out 5 2 Relay Input NO NC 5 2 1 Lock Relay Output Lock Relay Normally Open Status Figure 5 2 Normally Open Status Lock Relay...

Page 19: ...ormally Open Figure 5 4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5 5 Normally Closed Status Work Flow of Software For detailed information please see the user manual...

Page 20: ...20 Figure 6 1 Software Client Work Flow...

Page 21: ...r detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the official website and install the SADP according to the prompts Follow...

Page 22: ...heckbox of Enable DHCP 6 Input the password and click the Save button to activate your IP address modification STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own...

Page 23: ...l the software according to the prompts Follow the steps to activate the control panel Steps 1 Run the client software and the control panel of the software pops up as shown in the figure below 2 Clic...

Page 24: ...ton to start activation STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own choosing using a minimum of 8 characters including upper case letters lower case letter...

Page 25: ...p up the Network Parameter Modification interface 9 Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DH...