background image

 

Chapter 1. Product Description

 

 

1.1 Overview 

 

VS-AXESS-4D-ETL-PCB  is  a  powerful  and  stable  access  controller,  using  the  logical  architecture 

design. 

VS-AXESS-4D-ETL-PCB  is  designed  with  TCP/IP  network  interface  and  its  signal  processed  with 
special encryption and can be run offline. Anti-tampering function is also supported. 
 

 
1.2 Product Function 
 

 

The access controller is equipped with 32-bit high-speed processor 

 

Supports  TCP/IP  network  communication,  with  self-adaptive  network  interface.  The 

communication data is specially encrypted to relieve the concern of privacy leak 

 

Supports recognition and storage of card number with maximum length of 20 

 

The  access  controller  can  store  10  thousand  legal  cards  and  50  thousand  card  swiping 

records 

 

Supports first card open function, super card and super password function, online upgrade 

function and remote control of the doors 

 

Supports  Wiegand  interface  for  accessing  card  reader.  Wiegand  interface  supports  W26, 

W34 and is seamlessly compatible with third-party card reader with Wiegand interface 

 

Supports various card types as normal/ disabled/ blacklist/ patrol/ guest/ duress/ super card, 

etc. 

 

Various indicators to show different status 

 

Supports time synchronization via NTP, manual or automatic method 

 

Supports  record  storage  function  when  it  is  offline  and  insufficient  storage  space  storage 

alarm function 

 

The access controller has watchdog design 

 

Data can be permanently saved after the access controller is powered off. 

 

Supports I/O linkage, and event linkage 

 

Supports alarm of offline event exceeding 90% 

 

 
 
 
 
 
 

Summary of Contents for VS-AXESS-4D-ETL-PCB

Page 1: ...1 Four Door Access Controller Panel Board TCP IP Wiegand with Software and Power Supply Included 10 000 Users VS AXESS 4D ETL PCB Installation Manual...

Page 2: ...r TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS WITH ALL FAULTS AND ERRORS AND VISIONIS MAKES NO WARRANTIES EXPRESS...

Page 3: ...undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards liste...

Page 4: ...ow these precautions to prevent potential injury or material damage Tips The additional information as a complimentary of the contents Warnings Please adopt the power adapter from the legitimate facto...

Page 5: ...on of Cathode Lock 13 4 2 2 Installation of Anode Lock 14 4 3 CONNECTING THE EXTERNAL ALARM DEVICE 14 4 4 DOOR BUTTON WIRING DIAGRAM 15 4 5 THE CONNECTION OF MAGNETICS DETECTION 15 4 6 CONNECTING POWE...

Page 6: ...store 10 thousand legal cards and 50 thousand card swiping records Supports first card open function super card and super password function online upgrade function and remote control of the doors Supp...

Page 7: ...7...

Page 8: ...8 Chapter 2 Appearance 2 1 Component Description Access Controller Component Schematic Diagram The component schematic diagram is shown below Figure 2 1 VS AXESS 4D ETL PCB Component Schematic Diagram...

Page 9: ...scription No Component Description VS AXESS 4D ETL PCB 1 Door Lock 1 2 3 4 Indicator 2 Power Indicator 3 Network Indicator 4 Jumper Cap for Restoring Factory Settings 5 Working Indicator 6 Alarm Outpu...

Page 10: ...PCB Terminal Description Table 3 1 VS AXESS 4D ETL PCB Terminal Description No VS AXESS 4D ETL PCB A1 Alarm Input IN4 Alarm Input 4 A2 GND Grounding A3 IN3 Alarm Input 3 A4 IN2 Alarm Input 2 A5 GND G...

Page 11: ...r Button Input A29 GND Grounding A30 SENSOR Door Magnetic detector B1 Wiegand Card Reader 1 OK Indicator of Card Reader Control Output Valid Card Output B2 ERR Indicator of Card Reader Control Output...

Page 12: ...PWR Card Reader Power Output B28 GND C1 Power GND DC12V Grounding C2 12V DC12V Input D1 Alarm Output 4 COM4 Alarm Relay Output 4 Dry Contact D2 NO NC4 D3 Alarm Output 3 COM3 Alarm Relay Output 3 Dry...

Page 13: ...cess controller the Wiegand card reader 1 2 3 and 4 respectively correspond to the entering card readers of door 1 2 3 and 4 Chapter 4 External Device Wiring 4 1 Card Reader Wiring Figure 4 1 Wiring d...

Page 14: ...14 4 2 Installing Door Lock 4 2 1 Installation of Cathode Lock Figure 4 2 Wiring diagram of cathode lock...

Page 15: ...15 4 2 2 Installation of Anode Lock Figure 4 3 Wiring diagram of anode lock 4 3 Connecting the External Alarm Device Figure 4 4 External Alarm Device Connection...

Page 16: ...16 4 4 Door Button Wiring Diagram Figure 4 5 Power Button Connection 4 5 The Connection of Magnetics Detection Figure 4 6 Magnetics Connection...

Page 17: ...dware Steps 1 The jumper cap jumps from Normal to Initial 2 Disconnect the power and restart the access controller the controller buzzer buzzes a long warning 3 After the buzzer stops jump the jumper...

Page 18: ...the parameters to the default setting and all the device events are wiping out 5 2 Relay Input NO NC 5 2 1 Lock Relay Output Lock Relay Normally Open Status Figure 5 2 Normally Open Status Lock Relay...

Page 19: ...ormally Open Figure 5 4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5 5 Normally Closed Status Work Flow of Software For detailed information please see the user manual...

Page 20: ...20 Figure 6 1 Software Client Work Flow...

Page 21: ...r detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the official website and install the SADP according to the prompts Follow...

Page 22: ...heckbox of Enable DHCP 6 Input the password and click the Save button to activate your IP address modification STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own...

Page 23: ...l the software according to the prompts Follow the steps to activate the control panel Steps 1 Run the client software and the control panel of the software pops up as shown in the figure below 2 Clic...

Page 24: ...ton to start activation STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own choosing using a minimum of 8 characters including upper case letters lower case letter...

Page 25: ...p up the Network Parameter Modification interface 9 Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DH...

Reviews: