UltraDecoder Operators Manual
IP Setup
Issue : 3 (23/12/2015)
16
Ref : ULTD-ASUM-7001
Copyright © Vislink plc
7.5.
Decoder Communications Recovery Procedure
If communications to the internal decoder are lost, please perform the following steps to remedy
the fault.
•
Connect Eth. 1 to IP Video and Eth. 2 to Ethernet control using the supplied cables as per
section 7.1.
•
Copy onto a blank memory stick the file found here -
ftp://ftp.vislink.com/Vislink
Products/Ultradecoder/Recovery/
. The filename is 9261reset and is of length 0 Bytes.
•
Power on the unit.
•
When the unit has completed its boot process, on the front panel go to the
System|Presets|Restore Defaults menu and set the IP Defaults option to Yes. After about 20
seconds the unit will restart.
•
Once fully re-started plug the memory stick in at the rear USB socket when the unit is
already running.
•
Wait approximately 30 seconds, the alarm light should go from red to green, then remove
the memory stick and power cycle the unit.
•
Wait for the unit to reboot and the Decoder Communications will be recovered.
•
Finally on the front panel go to the System|Presets|Restore Defaults menu and set the
Restore Defaults option to Yes
•
Power cycle the unit.
•
Navigate to Unit Setup Menu | IP Options | IP Video output | Decoder IP Setup | Dest Port
•
Press enter then enter again.
•
The unit should now be functioning correctly.
•
The unit will now be configured to use the default IP addresses as shown below in the screen
shot from the web interface.