Static scanner OCD6000-F62-...
Detection range (schematic)
D
at
e of
ed
iti
on:
20
03
/0
7/
30
11
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: G49 621 776-0 • USA +1 330 4253555 • Sin65 67799091 • Internet http://www.pepperl-fuchs.com
4.2
Practically achievable limit distances
The maximum detection range of 4900 mm is reached it the horizontal angle
α
= 0 ° and the tilt angle
β
= 0 °.
When the OCD6000-F62 static scanner is used in electro-suspension webs, experi-
ence shows that this condition in particular is not always met. Depending on the curve
radii designed into the system, the following non-ideal conditions may arise:
• The reflector array is screwed out to the optimal alignment, i.e. the angle ß
≠
0°. This
results in a deterioration of the return beam properties of the reflector array itself
and reduces the projected surface of the reflectors.
• The optimally effective direction segments are not activated in the sensor, so that
the reflector array us moved out of the active measurement range.
These two circumstances may cause a reduction in the limit detection range.
(1): for pattern 85h.
One column, the middle one, is active.
(2): for pattern 83h or 84h.
The two outer columns are active.
(3): for pattern 82h.
The three middle columns are active.
All information above refers to an ambient temperature of 20 °C.
The specified distance error is not exceeded at the detection ranges indicated.
All values indicated here refer to deliveries in CW18/03 or later
Reflector
Dimension
(Foil F6000)
D
max
/mm
Vertical = 0 °
Horizontal = 0 °
D
max
/mm
Vertical = 0 °
Horizontal = +35 °
D
max
/mm
Vertical = 0 °
Horizontal = +40 °
D
max
/mm
Vertical = +6 °
Horizontal = 0 °
800 mm x 200 mm,
"face-on"
4900 (3)
4000 (1)
4500 (2)
3500 (2)
3900 (3)
3000 (1)
600 mm x 200 mm,
face-on
4500 (3)
3500 (1)
4000 (2)
3700 (2)
3500 (3)
2500 (1)
Semi-circle
∅
=380
mm
Height = 150 mm
2000 (3)
1200 (1)
800 (2)
-
1500 (3)
900 (1)
457 mm x 100 mm,
∅
=510 mm
1700 (3)
900 (1)
700 (2)
-
1300 (3)
700 (1)
320 mm x 100 mm,
∅
=510 mm
1100 (3)
800 (1)
550 (2)
-
850 (3)
600 (1)
Tabelle 4.1: Detection range