Commissioning
D
at
e of
ed
iti
on:
20
03
/0
7/
30
17
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: G49 621 776-0 • USA +1 330 4253555 • Sin65 67799091 • Internet http://www.pepperl-fuchs.com
Figure 6.3: Orientation of the reflector to the sensor
6.5
Switch on
After the operating voltage has been turned on, the sensor requires at least a warm-
up phase of approximately 5 minutes to achieve the specified accuracy of measure-
ment.
The sensor can be operated either in PC mode or in Standard mode. The switchover
is performed automatically by the sensor:
• If the sensor is connected to a PC with the corresponding software before it is tur-
ned on, the sensor remains in PC mode and returns the measured values to the
PC. A pre-condition is that the PC must send a valid command within about 0.8 se-
conds of when the sensor is turned on. If the sensor does not detect any PC within
approximately 0.8 after it is turned on, it switches automatically into the basic set-
ting, Standard mode.
• If the sensor is connected to the machine control system, it will automatically switch
into the basic setting BUS mode after 0.8 s. The sensor then uses the command
Get Distance 'C' to transmit the results of the measurement to the machine control
system.
wrong
right
Sensor
Receiver lens
Emitter lens