Installation overview
4.1
Point-to-point installation
The following overview can also be used as a check list. It lists all the steps that are
required for a complete installation of the VB34 reader.
1.
Read all the information in section "Safety instructions" at the beginning of this
manual.
2.
Install the reader using the supplied mounting material (Chapter 6.2.2).
3.
Adjust the reader to the correct reading distance for your model (Chapter 6.5).
4.
Wire the VB34 reader according to the following steps:
a) Connect the VB34 reader to a C-BOX 100 (Chapter 5.5) using one of the
accessory cables.
b) Wire the C-BOX 100 with all system signals and voltages required by your
application (trigger, inputs, outputs).
• Layout: Point-to-point, RS232 master/slave, Lonworks or fieldbus. For fur-
ther information, please refer to the sections in Chapter 6.7.
• Cabling: supply, primary serial interface – RS232, RS485 half duplex,
RS485 full duplex, 20 mA current loop, secondary interface, inputs, outputs
etc. For further information, please refer to the sections in Chapter 6.3.
5.
Configure the VB34 reader by installing and executing the configuration software
from the enclosed CD-ROM. The most important steps are:
• Select the codes to be read
• Configure the communication parameters
• Define the data format parameters
• In the test mode, adjust your VB34 reader to the application as described
in the configuration software.
6.
Complete the configuration program and start your application.
The installation is now complete.
4.2
Lonworks master/slave installation
The following overview can also be used as a check list. It lists all the steps that are
required for a complete installation of the VB34 reader.
1.
Perform steps 1 to 3 of the point-to-point installation.
2.
Wire the VB34 reader according to the following steps:
a) Connect the VB34 master reader to a C-BOX 100 (Chapter 5.5) using one of
the accessory cables.
b) Connect the BTK-6000 termination network to the VB34 master reader as
described under “Local Lonworks network” (Chapter 6.3.2).
c) Install and wire all slave readers required for your system configuration
d) Connect the BTK-6000 termination network to the last VB34 slave reader as