Barcode reader VB34
Installation
Da
te
of
issue
06/
1
3
/2005
49
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: G49 621 776-0 • USA +1 330 4253555 • Sin65 67799091 • Internet http://www.pepperl-fuchs.com
*) Light barrier (presence sensor) connected to the external trigger input .
**) The power pack can be connected directly via a separate cable to slave 2
(2 wires with at least 0,5 mm² for VS + GND).
Figure 6.54
Central light barrier with more than 2 readers and several power packs
The following figure shows a system with five readers, in which the master reader
receives the external signals (triggers, serial host signals, etc.) and is supplied
together with slave 1 and slave 2 via a C-BOX 100, while slave 3 and slave 4 are
connected via a CAB610X cable to a second power pack. This is necessary because
the C-BOX 100 can supply a maximum of 3 readers. The CAB611X cable connects
two separate groups: master, slave 1 and slave 2 as well as slave 3 and slave 4. In
this instance, the voltage supply is not continued, only the network and
synchronization signals are continued.
Slave 3 is connected via a customer-specific, 2-wire cable (0,5 mm²) to the power
pack (VS + GND).
*) Light barrier (presence sensor) connected to the external trigger input .
Figure 6.55
Central light barrier with more than 2 readers and central voltage supply