Figure 6.60
Flash™ trigger operating mode
6.8.4
D-Flash™ operating mode
In the D-Flash™ operating mode, the focus position is changed depending on the
measured distance (Dn in the following figure) between the reader and the object to
be read. This innovative and highly flexible function presents the software with
extensive possibilities. The D-Flash™ development is based upon the measured
minimum distance. This makes it suitable for a variety of applications. If necessary,
D-Flash™ can be tailored to meet the requirements of a specific application and
developed further.
Figure 6.61
Flash™ D-Flash™ operating mode
6.9
Key field and display
The VB34 key field makes it possible to call a menu using the following functions:
• Internal Net
• Test mode
These adjustments can also be made via the configuration software. (For additional
information, refer to Chapter 7.)
6.9.1
Internal Net
This sub menu is used to configure the VB34 reader in a master/slave network.
Here, the function of the reader (slave/master) in the network as well as, if configured
as a slave, the address are defined.
To call the Internal Net sub menu and configure the reader, carry out the following
steps:
1.
Keep the keys
▲
(arrow up) and
▼
(arrow down) depressed for 2 seconds at
the same time to call the main menu.
2.
Press the key
▲
(arrow up) or
▼
(arrow down) to select the “Internal Net ” menu
option and press ENT (Enter) to call the option.
3.
Press the keys
▲
(arrow up) or
▼
(arrow down) to select the “LonWAddrSel”
menu option and press ENT (Enter) to call the option.
4.
Select the reader function using the keys
▲
(arrow up) and
▼
(arrow down):