Option and default
Configuration Instructions
To
move the cursor
and
clear digits
, use the
"String Editor's"
keys as described in the
table in section 3.8.1.
21:IP RCVR 1
000.000.000.000
If equipped with GSM or Broadband/PowerLink modules, the PowerMaster can be programmed
to report the event messages defined in Report Events option (option 01) to two IP Receivers,
Visonic PowerManage model. IP reporting can be performed via GPRS (IP) channel using SIA
IP format or via Broadband IP channel using SIA IP or Visonic PowerNet format.
Enter the two IP addresses (000.000.000.000) of the IP Receiver 1 located at the 1
st
Monitoring
Station (21:IP RCVR 1) and IP Receiver 2 located at the 2
nd
Monitoring Station (22:IP RCVR 2).
Note:
You must enter the IP address of the receiver, even if you enter the Domain Name
System (DNS) server name where the receiver is installed. See option
28: RCVR 1 DNS
and
29: RCVR 2 DNS
for details on how to enter the DNS name.
22:IP RCVR 2
000.000.000.000
Master Installer only
26:SMS RCVR
If equipped with GSM module, the PowerMaster can be programmed to report the event
messages defined in Report Events option (option 01) to two SMS Receivers via the GSM SMS
channel using a special SMS text format. For further details concerning the SMS text format
please contact Visonic.
Enter the two telephone numbers (including area code – maximum 16 digits).of the SMS
Receiver 1 located at the 1
st
Monitoring Station (26:SMS RCVR 1) and SMS Receiver 2 located
at the 2
nd
Monitoring Station (27:SMS RCVR 2).
27:SMS RCVR2
Master Installer only
Note:
To enter the international prefix (
) at the 1
st
digit – key-in [#]
[1].
28:RCVR 1 DNS
Defines the domain names of RCVR1 and RCVR2. Enter a Domain name of up to 32
characters.
29:RCVR 2 DNS
Master Installer only
41:PSTN FORMAT
SIA
The PowerMaster can be programmed to report the event messages defined in Report Events
option (option 01) to two Alarm Format Receivers (see options 16 & 17) via PSTN telephone line
and/or GSM analog voice channel (if equipped with GSM module) using standard PSTN alarm
formats (i.e. SIA, 4/2 1900/1400; 4/2 1800/2300,
Contact-ID and Scancom).
Select which of the reporting formats the system will use to report the events to the two Alarm
Format Receivers
PSTN/GSM RCVR 1
and
PSTN/GSM RCVR 2.
Make sure that the receivers used by the Monitoring Stations are of the compatible models listed
below and that the receiver used can receive the format you select.
Compatible Alarm Format Receivers:
Osborne-Hoffman model 2000; Ademco Model 685; FBII Model CP220; Radionics Model
D6500; Sur-Gard Model SG-MLR2-DG and Silent Knight Model 9500.
Master Installer
only
Options:
SIA
;
4/2 1900/1400
;
4/2 1800/2300
;
Scancom
;
SIA text
and
Contact ID
.
D-306919 KP-250 PG2 Installer’s Guide