3.7 PGM Output
3.7.1 General Guidance
The "
05:OUTPUTS
" menu enables you to select events/conditions under which the PGM (programmable) output
will function and to select the internal sounder or STROBE light that will be activated according to how the system
is programmed.
3.7.2 Open Collector States
The PowerMaster provides an open collector output (active low) for control:
ON state (pulled to ground) = 0
OFF state:
no pullup = float
with pullup to Vcc = 1
3.7.3 Output Configuration
05:OUTPUS
⋅⋅⋅
Enable Expander
Enable or disable the PowerMaster-33 EXP internal wired expander module. When enabled the number of inputs and
outputs is increased to 8. This option is enabled by default.
Step 1
Step 2
Step 3
Select "05:OUTPUTS" menu
Select "Enable Expander " menu
KP-250 PG2 displays currently
selected setting Press
05:OUTPUTS
Enable Expander
OPTIONS
disable
Step 4
Step 5
Select whether to "enable" or
"disable" the expander
Press
to return to “Enable
Expander ” or
and select <OK>
to Exit.
OPTIONS
enable
OPTIONS
enable
3.7.4 Wired I/O Configuration
05:OUTPUS
⋅⋅⋅
Set EXP I/O PINS
Configure the EXP-33 expanders I/O types to either Zone or PGM. Pin #1 to #6 by default are configured to Zone, pin
#7 to #8 are configured to PGM.
Select the pin # and depending on the physical setup select either Zone or PGM.
56
D-306919 KP-250 PG2 Installer’s Guide