background image

2

D-300707

3.3 Enrolling the Detector ID into the Target 

Receiver's Memory 

Refer  to  the  target  receiver's  installation  instructions  and  follow  the 

procedure given there for "teaching" IDs. When you are instructed to 

initiate a transmission from the MCT-440 / MCT-441, press the Test / 

Silent button (see Figure 2).  

If  the  MCT-440/MCT-441  was  enrolled  to  PowerMax  or  P 

revision 2.9 and down, you have to cause the detector not to send 

AC failure messages, as follows: 
Continuously press the Test/Silent button for 10 seconds 

approximately, until a long beep (2 seconds) is heard. This beep 

indicates that the detector will not to send AC failure messages. To 

return to AC failure reporting capability, repeat the above action. 

Note: Propane and Butane gases are heavier than air and therefore 

fall to bottom. Methane gas is lighter than air and therefore rises up. 

Therefore, the installation locations are different, depending on the 

desired gas leak detection. 

4. PREPARATION FOR USE 

4.1 The LED Functions 

Once the unit is plugged into the wall outlet, the green power indicator 

flashes indicating that power is present and the unit is working. After an 

initial  ten  minute  warm-up  period,  the  unit  will  start  the  process  of 

continually sampling the air around it. 

Table 1. LED functions 

LED 

Function 

Green 

Flashing:  During  the  first  ten  minutes  (after  power 

connection) the green LED flashes (stabilization time). 

Constant light: The equipment is ready for operation: "Power ON". 

Orange  Illuminates in the event of trouble and emits a lengthy buzzer sound. 

Red 

(alarm) 

Flashes and a supplementary acoustic signal generator 

(transducer) sounds intermittently in the event of an alarm. 

4.2 Test Button and Muting Switch 

Press  down  on  the  Test  /  Silent  button  (see  Figure  2)  to  test  the 

operation of the indicators. The red and orange LEDs will flash and an 

acoustic  signal  tone  will  sound  intermittently.  This  action  should  be 

performed once a week. Use the Test / Silent button (see Figure 2) to 

switch off the acoustic alarm tone in the event of an alarm. The red 

LED  will  continue  to  flash  and  a  short  signal  tone  will  sound 

approximately every 45 seconds. 

Note: Do not test the MCT-440 / MCT-441 using a gas lighter. 

Note: In the event of a gas leakage, the smell of the gas may be in 

the air before the detector activates the alarm. 

5. MISCELLANEOUS COMMENTS 

Visonic Ltd. wireless systems are very reliable and are tested to high 

standards. However, due to low transmitting power and limited range 

(required  by  FCC  and  other  regulatory  authorities),  there  are  some 

limitations to be considered: 

A.  Receivers  may  be  blocked  by  radio  signals  occurring  on  or  near 

their operating frequencies, regardless of the digital code used. 

B.  A receiver responds only to one transmitted signal at a time. 

C.  Wireless devices should be tested regularly to determine whether 

there are sources of interference and to protect against faults. 

D.  It  is  recommended  to  unplug  the  detector  from  the  electricity 

mains before cleaning. Clean only using a dry cloth. Do not clean 

using a liquid substance. Clean externally only. 

The  user  is  cautioned  that  changes or modifications to the unit, not 

expressly  approved  by  Visonic  Ltd.,  could  void  the  user’s  FCC  or 

other authority to operate the equipment. 

 

W.E.E.E. Product Recycling Declaration 

For  information regarding the recycling  of this product  you must 

contact  the    company  from  which  you  orignially  purchased  it.  If 

you are discarding this product and not returning it for repair then 

you must ensure that it is returned as identified by your supplier. 

This product is not to be thrown away with everyday waste. 
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

 

 

Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its 

products hereinafter referred to as "the Product" or "Products" to be in conformance 

with  its  own  plans  and  specifications  and  to  be  free  of  defects  in  materials  and 

workmanship under normal use and service for a period of twelve months from the 

date  of  shipment  by  the  Manufacturer.    The  Manufacturer's  obligations  shall  be 

limited within the warranty period, at its option, to repair or replace the product or 

any part thereof. The Manufacturer shall not be responsible for dismantling and/or 

reinstallation charges. To exercise the warranty the product must be returned to the 

Manufacturer freight prepaid and insured. 

This  warranty  does  not  apply  in  the  following  cases:  improper  installation, 

misuse,  failure  to  follow  installation  and  operating  instructions,  alteration,  abuse, 

accident or tampering, and repair by anyone other than the Manufacturer. 

This warranty is exclusive and expressly in lieu of all other warranties, obligations or 

liabilities,  whether  written,  oral,  express  or  implied,  including  any  warranty  of 

merchantability or fitness for a particular purpose, or otherwise.  In no case shall the 

Manufacturer  be  liable to anyone for any consequential or incidental damages for 

breach of this warranty or any other warranties whatsoever, as aforesaid. 

This warranty shall not be modified, varied or extended, and the Manufacturer does 

not  authorize  any  person  to  act  on  its  behalf  in  the  modification,  variation  or 

extension  of  this  warranty.  This  warranty  shall  apply  to  the  Product  only.    All 

products,  accessories  or  attachments  of  others  used  in  conjunction  with  the 

Product,  including  batteries, shall be covered solely by their own warranty, if any.  

The Manufacturer shall not be liable for any damage or loss whatsoever, whether 

directly,  indirectly,  incidentally,  consequentially  or  otherwise,  caused  by  the 

malfunction of the Product due to products, accessories, or attachments of others, 

including batteries, used in conjunction with the Products. 

The  Manufacturer  does  not  represent  that  its  Product  may  not  be  compromised 

and/or  circumvented,  or  that  the  Product  will  prevent  any  death,  personal  and/or 

bodily  injury  and/or  damage  to  property  resulting  from  burglary,  robbery,  fire  or 

otherwise,  or  that  the  Product  will  in  all  cases  provide  adequate  warning  or 

protection.  User  understands  that  a  properly  installed  and  maintained  alarm  may 

only reduce the risk of events such as burglary, robbery, and fire without warning, 

but it is not insurance or a guarantee that such will not occur or that there will be no 

death, personal damage and/or damage to property as a result. 

The Manufacturer shall have no liability for any death, personal and/or bodily 

injury  and/or  damage  to  property  or  other  loss  whether  direct,  indirect, 

incidental,  consequential  or  otherwise,  based  on  a  claim  that  the  Product 

failed to function.  However, if the Manufacturer is held liable, whether directly or 

indirectly,  for any loss or damage arising under this limited warranty or otherwise, 

regardless of cause or origin, the Manufacturer's maximum liability shall not in any 

case exceed the purchase price of the Product, which shall be fixed as liquidated 

damages  and  not  as  a  penalty,  and  shall  be  the  complete  and  exclusive  remedy 

against the Manufacturer. 

Warning:  The  user  should  follow  the  installation  and  operation  instructions  and 

among  other  things  test the Product and the whole system at least once a week.  

For  various  reasons,  including,  but  not  limited  to,  changes  in  environmental 

conditions,  electric  or  electronic  disruptions  and  tampering,  the  Product  may  not 

perform  as  expected.    The  user  is  advised  to  take  all  necessary  precautions  for 

his/her safety and the protection of his/her property. 

6/91 

  

1. INTRODUCCIÓN

MCT-440  y  MCT-441  son  Detectores  de  Gas  completamente 

supervisados para proteger espacios interiores muy fáciles de instalar. 

El MCT-440 es un detector de Gas de Petróleo Líquido (LPG) diseñado 

para  enviar  alarmas  al  detectar  gas Butano o Propano. El MCT-441 

es un detector de gas natural diseñado para enviar alarmas al detectar 

gas  Metano.  Estos  detectores  pueden  usarse  en  apartamentos, 

caravanas, barcos o yates. 

Los detectores se alimentan con la red, con 220 VAC. Una pila interna 

de Litio sirve para informar de un fallo de corriente sólo (no alimenta el 

detector).  

El detector puede enviar los siguientes mensajes al panel de control del 

sistema de: Alarma de Gas, fallo del sensor de gas, fallo de corriente y 

batería baja. 

MCT-440  /  MCT-441  están  diseñados  para  su  montaje  en  pared  y 

deberían  colocarse  en  un  lugar  donde  haya  presencia  de  gas,  por 

ejemplo donde pueda haber fugas. 

En  caso  de  detección,  emite  un  zumbido  y  el  transmisor  integrado  

transmite un mensaje digital,

 

compuesto del PowerCode ID del  

detector  seguido  de  mensajes  de  estado.

 

Las  alarmas  y  otros  datos 

son,  por  tanto, remitidos al sistema de alarma. Un mensaje periódico 

de  supervisión  se  transmite  automáticamente  (ver  especificaciones) 

para  informar  al  sistema  de  alarma  de  la  participación  activa  de  la 

unidad en el sistema. 

Los detectores de gas MCT-440/MCT-441 tienen un código ID de  24 

bits,  seleccionado  aleatoriamente  desde  fábrica  de  entre  más  de  16 

millones de  combinaciones posibles. Este código es, por tanto, único y 

virtualmente imposible de reproducir. 
Los  receptores PowerCode compatibles se diseñan para “aprender” 

los específicos y responder solamente a ellos. 

2. ESPECIFICACIONES 

Compatibilidad:  Compatible  con  toda  la  familia  de  productos  del 

sistema de alarma PowerMax (PowerMax / P / PowerMax 

Pro  /  PowerMax  LE),  receptor  MCR-304,  receptor  MCR-308  o 

cualquier otro sistema de alarma PowerCode. 

Reviews: