MCW-570 

Automatic Flood Prevention System

 

 

Installation Instructions

 

1. INTRODUCTION 

1.1 Purpose and Use 

The MCW-570 is a fully supervised flood prevention system. It is triggered 
by up to 10 flood detectors that are located inside the protected site 
where presence of water flooding or leakage is probable. 
Upon cold/hot water flood detection, the system automatically shuts off 
the water supply to the protected site (by means of 1 or 2 cold/hot electro-
mechanical ball valves) and provides valve status indication, on the 
Control Unit and on the water valve(s).  
Turning ON the water supply, after repairing the water leak, is performed 
by pressing the OPEN button - see figure 1. 
Manual turning OFF the electro-mechanical ball valve is also possible, by 
pressing the CLOSE button - see figure 1. 
In case of power failure, it is possible, on some models, to manually 
open/close the valve (see Fig. 8). 
Optional - In addition to flood preventing, the system can also send ALARM, 
TROUBLE and LOW BATTERY signals to a remote control unit for remote 
indication (see figure 7). 

Up to 10 detectors

Flood
Sensor

WATER

MCT-550

Flood detector

WATER

Flood
Sensor

Close

button

Open

button

CONTROL UNIT

CLOSED LED

(red)

READY LED

(green)

MCT-550

Flood detector

Alarm, trouble and
low battery signals
to a remote
control panel
(option)

(see spec.)

 
 

1 or 2 cold/hot 

Electro-mechanical 

ball valves 

Figure 1 - Typical System Application

 

 

1.2 Kit Contents 

The MCW-570 system includes the following (see figure 1): 
a.  One Control Unit: In case of flood, the Control Unit receives signal 

from up to 10 wireless water flood detectors, sends OFF command to 
the water electro-mechanical valve(s) and provides indication of the 
closed valve(s). 

b.  One wireless flood detector MCT-550: The flood detector transmits 

an alarm signal to the Control Unit upon flood detection. 

c.  One cold water electro-mechanical ball valve: The electro-

mechanical ball valve is directly installed on pipe of central water 
supply. The valve automatically turns OFF the water supply in case of 
flood detection.  

d.  One power transformer - 9VAC output. 
Note: The system is designed for use with water valves that are supplied 
by the system manufacturer only.

 

1.3 LEDs Operation 

The Control Unit includes 2 main LED indicators (see Fig. 1), that function 
according to the following table: 

Valve Status 

Red LED 

Green LED 

Power-up 

High frequency 
flashing 

High frequency 
flashing 

Opened (no flood) 

Does not light 

Lights 

Closed Lights 

Lights 

During opening / closing 

High frequency 
flashing  

Lights 

Opened manually (override) by 
user although flood still exists 

Low frequency 
flashing  

Lights 

The Control Unit includes 2 additional LED indicators (in the receiver module - 
see Fig. 6), that are visible only after removal of the Control Unit cover: 

 Red SIGNAL / MEMORY STATUS LED - illuminates as long as the 

receiver receives signal from recognized flood detector. This LED is 
also used during the flood detectors “learning” process (described 
in par. 3.3). 

 Yellow MEMORY LOCATION STATUS LED indicator - used during 

the “learning” process. 

 

2. SPECIFICATIONS 

2.1 Control Unit Specifications 

RF SECTION 
Front-End Module
: Super-regenerative UHF receiver

.

 

Operating Frequency (MHz): 315, 433, 868.95 or other frequency 
according to local requirements in country of use

 .

 

DATA PROCESSING SECTION 
ID codes
: Over 16,000,000 possible 24-bit combinations 
Total Message Length: 36 bits 
ID Learning Capacity: Up to 10 different ID codes 

ELECTRICAL DATA 
Input Voltage
 (according to the electronic module type and cold water 
valve diameter):  

Valve diameter 

Electronic Module Cat. # 

Cold water 

Hot water 

Input Voltage 

E-200856 

3/4' or 1" 

1/2" 

9V / 0.35A Min. 

E-202355 

1-1/4" 

12VAC / 1A Min.

Current Drain @9VAC: Standby - 30 mA. During 2 valves 
closing/opening process only - up to 200 mA.

 

Relay Outputs: Form 1C (N.C. and N.O.)  
Relay Contact Ratings: 1A resistive, 30 VDC or AC. 
Status Outputs: 2, up to 100 mA each, open-collector type 

ELECTRO-MECHANICAL BALL VALVE 
Max water pressure
: 8 Bar 
Valve Diameter for Hot Water: 1/2"  
Valve Diameter for Cold Water: 3/4", 1" or 1-1/4". 
Valve closing Time: 5-11 seconds 

PHYSICAL 
Operating Temperatures
: 0˚C to 49˚C (32˚F to 120˚F)

 

Control Unit Dimensions (HxWxD): 108x165x38 mm (4-1/4x6-1/2x1-1/2”). 

Weight: Control Unit - 217 g (7.6 oz.), 3/4" WATER VALVE - 345g (12 
oz.), 1" WATER VALVE - 526g (18 oz.), 1-1/4" WATER VALVE 1.6Kg  
(3-1/2 Lb), AC ADAPTER - 200g (7 oz.). 
Control Unit Color: Off white  

COMPLIANCE WITH STANDARDS 
EN13564-1, EN13564-2, EN60950, EN300220, EN301489 

2.2 Flood Detector MCT-550 Specifications

 

TRANSMITTER 
Frequency (MHz)
: 315, 433, 868.95 or other frequency according to local 
requirements in country of use  
Transmitter's ID Code: 
24-bit digital word, over 16 million combinations, 
pulse width modulation. 
Overall Message Length: 
36 bits 
Message Repetition: 
One-shot transmission (default) or once every 3 
minutes (selectable). 
Supervision: 
Signaling at 60-minute intervals (U.S. version) or 15 minute 
interval (UK version), or according to the local standards. 
Response to Tamper Event: 
Tamper report every 3 minutes (until the 
tamper switch is restored). 

ELECTRICAL DATA 
Power Source:
 3V Lithium battery, Panasonic type CR-2 or equivalent.

 

Note: Dispose of used battery according the manufacturer's instructions. 
Nominal Battery Capacity: 750 mAh 
Current Drain: 6µA STBY, 17mA average in operation (including LED). 
Battery Life with LED on: 3 years (for typical use) 
Battery Supervision: Automatic reporting of battery condition data as 
part of any transmission. 
ALARM REPORT: 
Every 20 sec. for the first 3 minutes. Every 3 min. for the next 27 minutes. 
Alarm stops reporting after 30 min., or if the detector goes into "alarm restore". 
Length of Flood Sensor Cable: 3 meters (10 ft) 

Summary of Contents for MCW-570

Page 1: ... visible only after removal of the Control Unit cover Red SIGNAL MEMORY STATUS LED illuminates as long as the receiver receives signal from recognized flood detector This LED is also used during the flood detectors learning process described in par 3 3 Yellow MEMORY LOCATION STATUS LED indicator used during the learning process 2 SPECIFICATIONS 2 1 Control Unit Specifications RF SECTION Front End ...

Page 2: ...w the status of the selected location as follows Memory Status Red LED Response Location is free LED Flashes Location already contains an ID LED Lights steadily C If the memory status is free as shown in the above table initiate a transmission from the flood detector you wish to enroll in the selected location by inserting battery into the flood detector or if it s battery was already inserted cli...

Page 3: ...Base Cover CLOSED LED red READY LED green Remove screw Push near the 2 snap in teeth to remove the cover 2 1 Wire antenna Close cover and fasten with screw 4 3 Hold the base on mounting surface mark and drill 2 holes in mounting surface insert wall anchors if necessay and enter wires into the base through the wiring holes or wiring knockouts Attach the base to the mounting surface with two screws ...

Page 4: ...ot covered by this Warranty The Manufacturer does not represent that this Product may not be compromised and or circumvented or that the Product will prevent any death and or personal injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The Product properly installed and maintained only reduc...

Reviews: