9
Qubo Wall P/L
1/2021 (US)
4 Operation
⚠
WARNING
Injury can be caused and the merchandise
supports and/or system can be damaged if the
maximum load of the merchandise supports
is exceeded.
>
Observe the maximum load values of the
individual merchandise supports.
>
Do not exceed the maximum load of 265 lbs
per upright.
4.1 Cleaning
During the course of time, dust and deposits from
clothes hangers can settle on the merchandise supports.
In order that the goods on display do not become soiled,
the merchandise supports must be regularly cleaned.
Remove goods from the merchandise support.
1. Remove dirt on the merchandise support carefully
with a soft, dry cloth.
2. Remove stubborn dirt with a mild cleaning agent.
5 Dismantling and disposal
5.1 Dismantling
DANGER!
Danger to life from electrical power!
>
Pull out the plug from the electric socket.
>
Dismantle converters and power distributors
(where present).
5.2 Disposal
⚠
NOTE
If product components are improperly disposed
of they can pose a danger to the environment.
>
Ensure product components are disposed
of in a proper environmental manner or through
waste management specialists.
>
Send components that can be recycled
for recycling.
• Send metal components for recycling or scrapping.
• Send plastics for recycling.
• Have electrical and electronic components disposed
of by an approved waste management specialist.
• Dispose of remaining components sorted according
to the type of material.
6 Technical data
6.1 Dimensions
Converter dimensions, power-dependent
L
K
L
E
H
1
H
2
W
L
1
L
2
Fig. 11: Converter dimensions
Specification
96 W
Length [L1]
394 mm
15.512 inches
Length [L2]
364 mm
14.331 inches
Length [L3]
380 mm
14.961 inches
Width [W]
55 mm
2.165 inches
Height [H1]
87 mm
3.425 inches
Height [H2]
50 mm
1.969 inches
Length - connecting cable to the infeed
[L
E
]
500 mm
19.685 inches
Length - power cable [L
K
]
2000 mm
78.740 inches
6.2 Connection values
General
Specification
Value Unit
Operating voltage
120–240 V
Frequency
50–60 Hz
Nominal voltage (SELV)
24 V
Nominal current at power connection,
maximum
6 A
Mains side protection class; converter
96 W
II
Maximum housing temperature
(converter)
75
167
°C
°F
6.3 Load values
The maximum load applies including the dead weight
and the weight of all components
Wall upright
Specification
Load Unit
Maximum load
120
265
kg
lbs
Shelf
Specification
Load Unit
Maximum load
40
88
kg
lbs
Support bar
Specification
Load Unit
Maximum load
40
88
kg
lbs
Hanging rail with front arms
Specification
Load Unit
Maximum load
40
88
kg
lbs