0150-0202G
70
Vista Columbus Triplex
6.2 Vista Columbus Triplex WaveLink
A new feature with Triplex software version 5.00 is the Vista Columbus Triplex WaveLink. This feature
allows putting command codes in the URL when calling WaveBrowser to control actions the
WaveBrowser is going to perform.
This feature can be used by Web Developers to link various cameras to specific Web content. It will
also be used by the Vista Columbus Triplex Email feature to allow the recipient of an alarm email to
click on a link in the email, which causes the WaveBrowser to connect and play back at the time when
the alarm occurred.
Functionality
The traditional WaveBrowser URL is
http://<IP_Address>/wrcontrollite.ssi
. This URL will start the
WaveBrowser in the disconnected state. Triplex software version 5.00 supports command codes
placed after an underscore after
wrcontrollite
and before
.ssi
. In the following example, the options
are in bold.
Example: http://3.18.172.230/wrcontrollite_
c=1s=2a=3t=1361959858
.ssi.
The following table specifies the supported options:
Name
Code
Description
Example
Camera
c=<n>
Describes either the camera number for
fullscreen (1=Camera 1, …16=Camera
16) or the type of the multiscreen display
(100 = Multiscreen 16 large, 101=
Multiscreen 16 small, 102= Quad
screen)
c=10
Size
s=<n>
For fullscreen camera, describes the
size of the display (1=large, 2 =medium,
3= small)
s=2
Action
a=<n>
Describes the action the WaveBrowser
has to take:
0 No action
1 Normal Connection Play
2 Normal Connection Live
3 Normal Connection Goto
4 Live Connection
a=2
Time
t=<n>
When action is set to 3 (Goto), the time
specifies where to go in number of
seconds since 01/01/1960.
t=1361959858
Please Note: When an option is not specified, it will be set to 0.
When a normal connection is requested, but the Vista Columbus unit is already
connected via a normal connection, the WaveBrowser should open a live connection
instead.
NOTE
Summary of Contents for Columbus Triplex