background image

 

 

MJPEG Settings 

 

 
Select  the Full fish eye quality: 
Low (50%): 250KB/frame 
Medium (70%): 350KB/frame 
High (80%): 400KB/frame 
Max bandwidth at full frame rate: 12fps @ 400KB = 4.8Mbit/s 

 
H.264/MPEG4 Settings 

Compression Type: 
Select between either MPEG-4 or H.264 (you will be asked to save 
settings and restart camera to accept this change) 
 
Bitrate Mode: 
Select between CBR (Constant Bitrate) or VBR (Variable Bitrate) modes 

 
 
 
 
 
 
 
 
 

 
CBR (Constant Bitrate): 
In CBR mode only the Target BR column applies, so select the Target 
BR value you want for Fisheye and PTZ Streams, then click 'set' button 
to the right to save this setting.  
   

View  

CBR Target BR 

Full-Res Fisheye Control   

3000kbit/s (default)  

PTZ Streams Control  

1000kbit/s (default)  

Range selectable  

50 - 5000kbit/s 

 
 

Summary of Contents for Eclipse2

Page 1: ...Set up and user manual for the Eclipse2 camera Eclipse2 Manual ...

Page 2: ......

Page 3: ...shooting this product refer to this document and any other documentation provided If you still have questions please contact Norbain Technical Support and Sales Norbain Ltd 210 Wharfedale Road IQ Winnersh Wokingham Berkshire RG41 5TP England UK 44 0 118 912 5000 Netherland 31 0 76 579 2577 Belgium 32 0 3 369 8080 South Africa 27 0 11 887 1546 Portugal 351 234 301900 Spain 34 91 503 06 78 Middle Ea...

Page 4: ... the product end of life This applies to your product and any peripherals marked with this symbol Do not dispose of these products as unsorted municipal waste CE Mark This apparatus is manufactured to comply with the radio interference A Declaration of Conformity in accordance with the following EU standards has been made The manufacturer declares that the product supplied with this document is co...

Page 5: ...Any wall or shelf mounting accessory equipment should be installed using the manufacture s Instructions Care should be used when moving heavy equipment Quick stops excessive force and uneven surfaces may cause the equipment to fall causing serious injury to persons and objects 6 VENTILATION Openings in the equipment if any are provided for ventilation to ensure reliable operation of the unit and t...

Page 6: ...k 12 SERVICING Do not attempt to service the video monitor or equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 13 DAMAGE REQUIRING SERVICE Unplug the equipment from the wall outlet and refer servicing to qualified service personnel under the Following conditions A When the power supply cord or t...

Page 7: ...HAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO 18 Use certified Listed Class 2 power supply transformer only TABLE OF CONTENTS INTRODUCTION 1 MINIMUM PC LAPTOP SPEC 1 INSTALLATION CONNECTION 2 CONNECTING TO THE ECLIPSE 2 4 NETWORK SETTINGS 5 CAMERA SET UP 7 SPECIFICATION 16 LINE DRAWING 18 FACTORY DEFAULT 18 CAMERA STREAMS 19 ...

Page 8: ... dynamic privacy zones Up to 20 users with selectable access levels Ceiling Wall or Table orientation PoE or 12 24VDC operation 6W Compact dimensions 147 5 Ø x 54 H mm Multi language support English Russian German French Spanish Italian Dutch Portuguese MINIMUM PC LAPTOP SPEC Recommended minimum specification OS Windows 7 Professional CPU Intel i3 Dual Core 2Ghz or above Display 1024 x 768 256MB s...

Page 9: ... browser The Eclipse2 is a sealed camera with no internal moving parts and designed to be surface mounted either on a wall ceiling or table floor Using the provided screws or others to suit the mounting location ensuring the camera is securely fitted If the Eclipse 2 is wall mounted putting the status LED in the 12 o clock position will ensure the camera is the correct way up Fig1 Cross section of...

Page 10: ...over Ethernet PoE but can also be powered by 12 24VDC using the additional red and black wires in the lead PoE supply should be provided by equipment compliant with IEEE 802 3AF In addition to the RJ45 and power cores there are also the alarm in alarm out and common wires Wire Description Red 12 24VDC Black 0V Green Alarm Input Yellow Alarm Output Brown Alarm Common Orange on some models White on ...

Page 11: ... to use the appropriate subnet together with a browser such as Firefox or Internet Explorer On the browser address bar simply type in the IP address of the camera A username and password will be required to access the camera by default these are Username Admin Password Admin Or Load the Eclipse2 utility from the disc onto your PC Laptop 1 Run the program 2 Click the Rediscover button 3 Highlight t...

Page 12: ...ay the MJPEG streams Java runtime environment is required for this and must be installed separately if this is not already present on the PC Laptop Once this is installed and the webpage refreshed you will be prompted to install the java applet 2 ePTZ control UP DOWN LEFT RIGHT ZOOM of the camera will require you to use the PTZ Zoom buttons on the camera web page and you will not be able to click ...

Page 13: ...O CAMERA button 3 Warning comes telling you restart camera close this 4 Click SAVE SETTINGS button 5 Click RESTART CAMERA button 6 The camera will then restart after approx 2mins 7 Reconnect using the new IP address Fig3 IP address change schematic ...

Page 14: ...e that can be used with the following de warped streams VIEW 1 VIEW 2 VIEW 3 VIEW 4 4 x VIEW quad To set a preset 1 Tick the save box 2 ePTZ to the required point 3 Click on the preset button 1 to10 that you wish to save 4 Untick the save box 5 Preset is now saved ...

Page 15: ...ers e g Firefox ePTZ can be achieved by holding the mouse cursor on the displayed image and left clicking the mouse to navigate around the image the scroll wheel acts as the zoom in out function Mount Ceiling Wall Table This orientates both the image and ePTZ functionality if wall mounted ensure the LED is in the 12 o clock position as this will have the image the correct way up View Select This a...

Page 16: ...ch individual view can be adjusted via a sliding scale for Brightness Contrast Quality Auto Exposure Tick to enable this assists with the picture level in varying lighting conditions Low Light Tick to enable this turns the camera into permanent monochrome mode Global Image settings The following settings can be adjusted via a sliding scale which is applied globally to ALL streams Exposure Saturati...

Page 17: ...o 60 characters DHCP Tick to enable if your network supports DHCP Default Port Change the port to suit your network Defaulted to TCP IP 80 HTTPS 443 RTSP Server Change the port to suit your network Defaulted to 8554 NOTE to ensure any changes to the network page are retained please refer to page 5 of this manual for the correct procedure ...

Page 18: ... is also Admin and this password may be changed If this password is changed it can only be restored by restoring factory defaults via the reset button on the back of the camera see page 18 20 further additional users can be added if required Camera Details This will list the following information Software version OS Version Hardware Firmware Website Pages Camera Date Time Set current date and time...

Page 19: ...to save settings and restart camera to accept this change Bitrate Mode Select between CBR Constant Bitrate or VBR Variable Bitrate modes CBR Constant Bitrate In CBR mode only the Target BR column applies so select the Target BR value you want for Fisheye and PTZ Streams then click set button to the right to save this setting View CBR Target BR Full Res Fisheye Control 3000kbit s default PTZ Stream...

Page 20: ...lt Range selectable 50 12000kbit s 50 90 In VBR the camera encodes at the Target Quality unless the size of the encoded data is greater than the Max BR It then temporarily reduces the image quality to keep under the maximum bit rate Once quality is below a set level the encoder drops frames to keep within the Max BR figure Misc Settings Flicker Frequency Off 50Hz 60Hz Disable Status LED Tick box t...

Page 21: ...box which zone you want to apply 2 Using the mouse click 4 points on the image that you want to obscure lines are automatically joined up 3 Click save if you wish to accept click clear if you want to amend If you wish to delete a previously applied privacy zone select via the drop down box and click the clear button The clear all regions button deletes all previously stored privacy zones ...

Page 22: ... 4 With this set the alarm output signal will be switched when the alarm is triggered 5 Set the duration of the alarm 6 FTP Set whether images are to be sent via FTP during the alarm period The FTP server details must be set up on the Network page to use this feature a Set the View number to be sent via FTP see Video Streams in section 4 below b Set the number of Frames per second to be set via FT...

Page 23: ...ide bars Languages English Russian German French Spanish Italian Dutch Portuguese Status LED Operation On Off Preset Positions 10 de warped streams 1 8 inclusive Privacy Zones 10 dynamic areas Orientation Ceiling Wall Table Video Compression MJPEG H 264 or MPEG 4 Frame rate 12 5fps at Max Res Streaming Multiple simultaneous ePTZ and Panoramic streams Security Password Protection HTTPS encryption P...

Page 24: ...PTZ and panoramic view creation in NVR playback software Alarms 1 x Alarm Input 1 x Alarm Output Alarm Triggers External input Alarm Events File upload via FTP external output activation General Power PoE IEEE 802 3af Class 2 12 24VDC Max 6W Colour RAL7035 Construction Die Cast Aluminium Weight net 650g Weight gross 900g Dimensions unit 147 5mm Ø 54mm height Dimensions boxed 170 W x 170 H x 170 D ...

Page 25: ...eave powered up 2 Remove screw entirely highlighted below 3 Insert pin paperclip and hold until the LED cycles from red to amber to green approx 10 secs 4 Camera will then reboot this can take up to 2mins 5 Reconnect to the camera refer to page 4 of this manual if unsure ...

Page 26: ...t from 0 to 13 0 Full Fisheye 2144x1944 1 4 640x480 de warped ePTZ 5 8 320x240 de warped ePTZ 9 640x480 Fisheye 10 11 640x240 180 Panorama 12 1280x720 HD de warped ePTZ 13 1280x240 HD 360 Panorama maxfps can be set at 1 2 4 6 12 RTSP MPEG4 or H 264 rtsp ipaddress 8554 stream0 Stream number can be set from 0 to 13 0 Full Fisheye 2144x1944 1 4 640x480 de warped ePTZ 5 8 320x240 de warped ePTZ 9 640x...

Page 27: ...Eclipse 2 Manual V1 0 April 2012 subject to change without notice ...

Reviews: