background image

Vista SmartCF

RT

Digital Video Transmission System

VLS2-02RTCF3G 

Quick Installation Guide

Summary of Contents for SmartCF VLS2-02RTCF3G

Page 1: ...Vista SmartCFRT Digital Video Transmission System VLS2 02RTCF3G Quick Installation Guide ...

Page 2: ......

Page 3: ...marks trade names proprietary names and article names reproduced in this manual are reserved and are protected by the relevant laws governing trade names patents registered designs and industrial designs This documentation may not be copied translated duplicated or transferred in any other way to electronic media or any other device either completely or partially without previous written permissio...

Page 4: ...Quick Installation Guide Vista ii SmartCFRT This page is intentionally left blank ...

Page 5: ...ick Installation Guide 3 1 1 Front View and Description 4 1 2 Rear View and Description 5 1 3 Included in Delivery 7 1 4 Optional Accessories 7 1 5 Standard Switching for Control Inputs 8 1 6 Wiring Variants for Voltage monitored Control Inputs 8 1 7 Initial Setup Operation 9 ...

Page 6: ...Quick Installation Guide Vista 2 SmartCFRT This page is intentionally left blank ...

Page 7: ...ctv com for the current firmware version Commissioning Information on commissioning the device follows on page 9 Manual Detailed information going beyond the scope of this quick installation guide can be found in the full device manual or the full software manual both of which can be found on the installation CD in PDF format Connection options for cameras The SmartCFRT can be equipped with a maxi...

Page 8: ...for example prior to switching off the video system l A LED chaser light from left to right and from right to left indicates hard disk initialisation 4 V2 LED yellow 5 LED Record blue An illuminated Record LED indicates storage medium write access e g caused by image recording or system related access such as transmission of date and time data 6 LED Online blue A permanently illuminated LED indica...

Page 9: ...egrated USB power supply Power Over eSATA 6 RF antenna terminal Antenna terminal SMA for 3G UMTS mobile network only in combination with 3G GPS Module 7 GPS antenna terminal Antenna terminal SMA for GPS signals only in combination with 3G GPS Module 8 USB USB port type A reserved for other applications Connection of an additional IP camera or of the two maximum possible IP cameras is effected via ...

Page 10: ...C Power Ground 15 R1 Common Relay Device configuration allows you to allocate the following functions to any relay l Manual remote control withSmartControl SmartControl PRO or SmartControl CLIENT distinguishing between switch and pushbutton functions l Switching to at least one SmartControl receiver unit with active online connection l Error relay 16 R1 normally open Relay 17 R1 normally closed Re...

Page 11: ...ccessories Component Description VLS AUDIOBRD Audio module for bidirectional transmission of digital audio signals in voice quality HDD CASE In preparation External housing for hard disk removable frame which depending on the chosen application can be fitted with removable hard disks of type HDD Tray static or HDD TrayM mobile VLS2 DR1TB VLS2 DR2TB VLS2 DR4TB In preparation Removable hard disk for...

Page 12: ...ly closed For circuitry with a resistance a distinction is made between two different states l Not triggered The figures show the safe state in each case not triggered of the detector line or the control input for the variants Normally opened and Normally closed l Camera alarm If the Normally opened or Normally closed contact is operated depending on the type of circuit a camera alarm is activated...

Page 13: ...er options dialogue window the option Port A Confirm the changes made using OK Relevant changes Option Description Network Enable TCP IP Enables TCP IP connection including USB direct connection and 3G UMTS to the device 1 7 2 USB connection from SmartControl to the device Driver installation For a USB connection if required the corresponding driver must be installed on your receiver PC The driver...

Page 14: ...the TCP IP crosslink cable l Note down the current settings for the IP address and Subnet mask l Change these settings l IP address e g 192 168 31 66 l Subnet mask 255 255 255 0 Establishing the connection to the device Start SmartControl Click on the Dial button In the Transmitter index dialogue window click on the Add button and then select from the next selection menu Add new transmitter In the...

Page 15: ... made using OK so that the data is transmitted to the device For detailed information on device programming if necessary please consult Chapter 7 of the SmartControl software manual 1 7 5 Programming of 3G UMTS connection of the device only SmartCFRT with 3G GPS Module After establishing the connection to the device click on the Setup button to open the Recorder settings dialogue window To program...

Page 16: ...0V1 D2 C1S0 0 IFC 2 2 generally ensures correct initialisation of the internal 3G UMTS modem l Initialisation command 2 A further command sequence enables further provider dependent adjustment of the internal 3G UMTS modem where necessary l Reset Adapter every This drop down list menu allows you to specify how often you want to reset the internal 3G UMTS modem Certain installations may require the...

Page 17: ...ened Model alarm using Aux in1 l Take the relevant transmission routes into operation l Check the dial up number s for alarms Connections Phone IP numbers if necessary to your receiver PC or to the control station See Parameter settings for the device on page 11 l Ensure that the device is not in the alarm status l Close the connection from Aux in1 and to the relevant device ground for at least 50...

Page 18: ...Quick Installation Guide Vista 14 SmartCFRT This page is intentionally left blank ...

Page 19: ......

Page 20: ...8 3347 Printed in Germany Quick Installation Guide 4 08 Vista Norbain SD Ltd 210 Wharfdale Winnersh Triangle Wokingham Berkshire RG41 5TP England Phone 44 0 118 912 5000 Fax 44 0 118 912 5001 ...