Air Handler
2
table 5
Model
Airflow Tonnage
Range
Motor @ 230V 1Ph 60Hz
DD Blower Wheel
(inch)
HP
FLA
2.0
1/17
0.52
9.5×8
3.0
1/2
3.6
10×10
3.5
3/4
4.6
11×11
4.
5
3/4
4.6
11×11
The air flow of indoor unit
table 6
Model
VAF-24A308I VAF-36A308I VAF-42A308I VAF-55A308I
ESP(in.wg)
Air volume(CFM)
Air volume(CFM)
Air volume(CFM)
Air volume(CFM)
0
808.4
1287.9
1377.4
1504.5
0.04
776.2
1250.8
1367.8
1483.8
0.08
742.1
1218.0
1339.6
1462.7
0.12
706.8
1181.2
1326.8
1441.6
0.16
666.6
1147
1300.4
1420.5
0.2
623.4
1113.1
1288.6
1400.6
0.24
576.4
1083.0
1271.4
1379.4
0.28
514.1
1055.8
1242.8
1357.8
0.32
452.3
1014.8
1214.3
1335.3
0.36
384.2
963.1
1208.1
1312.1
0.4
306.4
906.5
1182.5
1288.5
Notes:
①
Based upon W/nominal tonnage, dry coil and filter should be installed.
②
Use 0.96 as approximate CFM correction factor for wet coil.
See the following table for how to set the DIP switch of the unit
VAF-36A308I
and
VAF-42A308I
:
table 7
Model/DIP Switch
COOL
HEAT
/
/
Note:
The black part presents the switch rod.
VAF-24A308I
VAF-36A308I
VAF-42A308I
VAF-55A308I
VAF-24A308I
VAF-36A308I
VAF-42A308I
VAF-55A308I