background image

2.1 Connection 

 

 

Connection Cable 

 
 
 
 
 
 
 
 
 
 
 
 
 

NO 

Wire Color 

Description 

Yellow 

Ethernet, RJ-45 port compatible with 10/100Mbps having PoE 
functionality. Modular Jack 

Red: 
AC24V/DC12V 
White: AC24V/GND 

Main Power, 3 pin terminal,   

Pink: GND 
Gray: Alarm Input 
Brown: GND 
Yellow: Alarm Out 

Alarm Input and Output, 4pin terminal. 

Red : Audio In 
White : Audio Out 
Black : GND 

Audio Input and Output Cable. 

 

 

Micro SD memory slot on the Board

 

Card Slot for Micro SD memory: Socket 

“J15” 

 

•    Connecting to the RJ-45 
 

Connect a standard RJ-45 cable to the network port of the network camera. Generally a 

 

cross-over cable is used for directly connection to PC, while a direct cable is used for connection 

 

to a hub.

 

 

You can also use a router featuring PoE (Power over Ethernet) to supply power to the camera.

 

 
•    Connecting Alarms 
 

AI(Alarm In) : 

 

You can use external devices to signal the network camera to react on events. Mechanical or 

 

electrical switches can be wired to the AI (Alarm In) and G (Ground) connectors. 

 

G(Ground) : 

 

Connect the ground side of the alarm input and/or alarm output to the G (Ground) connector. 

 

Alarm Out : 

 

The network camera can activate external devices such as buzzers or lights. Connect the device 

  to the AO (Alarm Out) and G (Ground) connectors. 

•    Connecting the Power 

Connect the power of DC12V or AC24V for the network camera. Connect the po) pole to 
the ‘+’ position and the negative(-) pole to the ‘-‘ position for the DC power. 
 

 

Be careful not to reverse the polarity when you connect the power cable. 

 

You can also use a router featuring PoE (Power over Ethernet) to supply power to the 
camera. 

 

The heater will operate properly only by the power source of AC 24V. 

Summary of Contents for VK2-3MPVRDIR3V9F

Page 1: ...Please read this manual thoroughly before use and keep it handy for future reference VK2 3MPVRDIR3V9F Quick Guide ...

Page 2: ...2 ...

Page 3: ... to make sure that you received the complete system including all components shown above Contents in the installation CD 1 The Network Camera User s Manual 2 The SmartManager User s Manual 3 The VK2_Client User s Manual 4 The SmartManager Installation software 5 The VK2 Client Installation software Note Check your package to make sure that you received the complete system including all components ...

Page 4: ... PoE Power over Ethernet to supply power to the camera Connecting Alarms AI Alarm In You can use external devices to signal the network camera to react on events Mechanical or electrical switches can be wired to the AI Alarm In and G Ground connectors G Ground Connect the ground side of the alarm input and or alarm output to the G Ground connector Alarm Out The network camera can activate external...

Page 5: ...tput port of the OSD Controller 3 Press the SET button to access main Menu 4 Change Camera ID and IP Address You can change the Name or Title and IP address of the camera Using the buttons on the controller you can change the parameters 5 Select SAVE or CANCEL to exit the Main Menu Video Output is used for an easy zoom and focus control when installing lens Video Output is restricted to 704x480 57...

Page 6: ...e operation through the network When a camera is first connected to the network it has no IP address So it is necessary to allocate an IP address to the device with the Smart Manager utility on the CD The factory default IP is 192 168 30 220 1 Connect the Network Camera device to the network and power up 2 Start SmartManager utility All Programs SmartManager SmartManager the main window will be di...

Page 7: ... browsers are Internet Explorer Safari Firefox Opera and Google Chrome with Windows 3 1 Access from a browser 1 Start a browser Internet Explorer 2 Enter the IP address or host name of the Network Camera in the Location Address field of your browser 3 You can see a starting page Click Live View or Setup to enter web page 4 The network camera s Live View page appears in your browser ...

Page 8: ...mera is accessed for the setup at the first time Enter your admin name and password set by the administrator Note The default administrator username and password is admin If the password is lost the Network Camera must be reset to the factory default settings See 3 6 Resetting to the Factory Default Settings 3 4 Live View Page The live view page comes in several screen modes 1920x1080 1280x1024 12...

Page 9: ... on the live screen The Full Screen button causes the video image to fill the entire screen area No other windows will be visible Press the Esc button on the computer keyboard to cancel full screen view The Manual Trigger button activates a pop up window to manually start or stop the event The Remote Focus button enables users to adjust focus and zoom remotely via network The Smart Focus button re...

Page 10: ...ting Zoom Click button to zoom out and click button to zoom in The focus is moved slightly after adjusting zoom adjust the focus again as necessary Adjusting Focus Click button for far focus and click button to near focus Fine Focus Click Fine Focus to fine tune and readjust focus automatically Note Click the button in the live screen to set the focus to the optimum position ...

Page 11: ... To reset the Network Camera to the original factory settings go to the Setup System Maintenance web page described in 3 5 5 System Maintenance or use the Reset button SW1 on the board of the dome camera as described below Using the Reset Button Follow the instructions below to reset the Network Camera to the factory default settings using the Reset button 1 Power off the Network Camera by disconn...

Page 12: ...12 Norbain SD Ltd 210 Wharfedale Road Winnersh Triangle Wokingham RG41 5TP 01189 125 000 ...

Reviews: