1. AUGER LIGHT:
This green light will flash in conjunction with the auger pulse.
2. MODE LIGHT:
Responsible for signaling the state of the control board. When the light is flashing the
stove is in an automatic start mode or the thermostat has control of the unit. When the light is solid,
the Heat Level Setting can be altered.
3. THERMOSTAT SWITCH:
Used to set the unit’s controls to one of three mode settings; manual,
high/low, or auto/off.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
4. FEED RATE TRIM BUTTON:
Used to change the feed rate
trims in 1⁄4 second increments for all feed settings. When
this button is pressed, all the light will light up on the Heat
Output Indicator except for the one that shows the current
setting; the default setting is the number 4 light. To adjust
the setting hold the Feed Rate Trim button down and press
the Heat Level up or down buttons to adjust the setting.
5. COMBUSTION BLOWER TRIM BUTTON:
Used to
change the Combustion Blower trims in 5 volt increments
for all feed settings until it reaches line voltage. When this
button is pressed, all the light will light up on the Heat
Output Indicator except for the one that shows the current
setting; the default setting is the number 2 light. To adjust
the setting hold the Combustion Blower Trim button down
and press the Heat Level up or down buttons to adjust the
setting.
6. ON/OFF BUTTON:
Used to turn the unit ON and OFF.
7. ROOM AIR FAN ON/OFF BUTTON:
Used to turn
convection fan on or off.
8. HEAT LEVEL ADJUSTMENT BUTTONS:
When pressed,
will change the heat level setting of the unit up or down.
9. HEAT OUTPUT INDICATOR:
Shows the present heat
output setting.
Figure 3: Circuit Board Control Panel Decal.
O
PERATING
Y
OUR
P
ELLET
S
TOVE
:
PRE-BURN INSTRUCTIONS
: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
Note:
The thermostat mode can be changed during normal operation.
Figure 4: Thermostat Switch in
MANUAL position.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START:
Press the ON / OFF button. The stove will turn on. The
system light will flash. The Auger Light will flash with each pulse of the
auger (the Auger Feed Rate is pre-programmed during start-up). The
Heat Level Indicator will show the Heat Level that the stove will run at
after start-up and can be adjusted but the change will not take affect
until the start -up has finished.