1 March, 2005
V1682OPMA.doc
Page 19 of 32
Figure 4.5 – Audio PPM display
It should be noted that the display is always in dBu (relative to 0.775V) irrespective of the input domain
(analogue or digital), more importantly, the levels are effected by the MAL (Maximum Analogue Level)
setting if a digital input format is being used. For more information on MAL see Sec. 4.4.
The V1681 generator always outputs audio tone at 0dBu in both analogue and digital domains, so if the
audio system is set up correctly, the meters should read 0dBu as shown in Figure 4.5.