WATER QUALITY AND MAINTENANCE

G E NE RAL

GUID E L INES

FOR

WAT E R

QUALITY MAINTENANCE

Maintaining water quality within specific limits will
enhance your enjoyment and prolong the life of
the spa. Safe, comfortable and clean spa water is
a fairly simple task to achieve, but it does require
attention because of the numerous factors that
can alter it. There is no one formula to be
followed because of the variables, i.e. quality of
the water used to fill the spa, water temperature,
user load, etc. For specific guidelines for water
quality maintenance, consult your Vita Spa dealer
who can assist you to develop a program based
on your specific needs. Disregard for water
maintenance will result in poor soaking
conditions, damage your spa investment, and
possibly void your warranty.

SPA WATER MAINTENANCE CONSISTS OF
T HREE SEPA RATE, EAS ILY DEVELO PE D
PROGRAMS:

Sanitizing and maintaining a safe level of
sanitizer in the spa water. Balancing the pH and
maintaining the recommended mineral content
level. Achieving and maintaining water clarity.

SANITIZING

To destroy bacteria and organic compounds in
the spa water, a sanitizer must be used regularly.
The use of ozone as an oxidizer has proven to be
an effective method to help maintain water
cleanliness, but a residual chemical sanitizer such
as bromine, the most common sanitizer used in
spas, must be used in conjunction with oz o n e .
Do not drop bromine tablets directly in the spa.
The use of a floater is required to dispense safely
and properly the right amount of bromine in the
spa water. A bromine residual of 2 to 3 PPM is
generally considered desirable. A two-part
bromine system or granular chlorine (Dichlor) are
also acceptable sanitizers.

pH CONTROL

pH is a measure of acidity and alkalinity of the
spa water. The recommended pH for spa water
is 7.4 to 7.6 PPM.

Below 7.0 (considered

neutral), the spa water is acidic and can cause
damage to the heating system. Above 7.8 the
water is too alkaline and can result in cloudy
water and scale formation on the spa shell,
heater and cover.

IMP O R TANT:

NEVER

USE

CHLO RINE

TABLETS (TRICHLOR) IN YOUR SPA.

This chemical can have an extremely corrosive
effect on certain materials in the spa. Also, the
use of liquids, chlorine or acid, are not
recommended. Damage caused by use of any
chemical, is not covered under the spa warranty.

OZONE WATER PURIFICATION SYSTEM

The use of Ozone has become very popular in
spas as a water treatment method. In addition to
being a strong oxidizer, Ozone makes spa waters
easier to maintain, creates “softer” water with no
skin or eye irritation, reduces chemical sanitizer
by up to 70% and helps provide a pleasant,
sparkling environment.

Used in conjunction with a residual chemical
sanitizer such as bromine, Ozone provides the
safest and most effective way to ensure
maximum water quality.

Your spa comes equipped with a 24 - h o u r
BIOZONE water purification system, the most
efficient and effective system to introduce ozone
in spa water.  After being filtered and heated, the
spa water goes through a venturi ozone injector
known as a “Vitazone Injector”. The Vitazone
Injector draws ozone from a high efficiency
ozone generator and mixes it under pressure
with the water. The ozonated water travels
around the spa before it is discharged into the
main body of water. The Vitazone injector and
travel

time

provide

optimum

oz o n a t i o n

effectiveness with minimum undissolved ozone
release.

Summary of Contents for GRAPHIC SERIES

Page 1: ...h e a l t h a n d r e l a x a t i o n f o r l i f e GRAPHIC SERIES OWNER S MANUAL VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Page 2: ......

Page 3: ...____________________________________ TELEPHONE ___________________________________________ SERIAL ______________________________________________ MODEL _____________________________________________ To...

Page 4: ......

Page 5: ...16 F Cluster 16 G Tension Ease 16 H Air Control 17 I Waterfall Operation 17 J Aromatherapy Injector 17 VitAroma Therapy System 18 Water Purification System 19 Sparkle Clear 19 SPA MAINTENANCE Filter M...

Page 6: ......

Page 7: ...nance We suggest that you take some time to carefully review it Please keep this manual available for reference If you have any questions regarding your Vita Spa set up operations or maintenance pleas...

Page 8: ...r attached to the wire connector on the terminal box that is provided for this purpose National Electrical Code ANSI NMFP A70 1993 DANGER RISK OF ELECTRICAL SHOCK Do not permit any electrical applianc...

Page 9: ...than normal body temperature can result in a dangerous condition known as HYPERT HE RMIA The causes symptoms and effects of hyperthermia may be described as follows Hyperthermia occurs when the intern...

Page 10: ...mended The wire size for the distance of the wire run must conform to NEC and local electrical codes 5 To ensure proper connections use copper conductors only DO NOT USE ALUMINUM WIRE 6 The spas power...

Page 11: ...wn straps Utilizing the cover anytime the spa is not in use will reduce heat loss and thereby reduce the amount of running time required to make up that loss by the heating system Keep cover fastened...

Page 12: ...f the newest a latest technological topside control for hot tub performance and personal comfort Before we start getting to know the operations of the topside control let s go over a few things The si...

Page 13: ...to 30 seconds to be completed If at anytime you choose to change your viewing setting to the factory default merely press RESET to return to the default settings So now let s go back to the beginning...

Page 14: ...p to view directions for this screen Press Back to return to Mood display Press LIGHTS to cycle through light sequences Use ON OFF button to activate lights Use ARROWS to select color The upper right...

Page 15: ...GE 9 Press MEDIA to enter stereo mode Use BACK to return to MOOD display Use SOURCE to cycle through Line TV AM and FM Use SELECT to change from media to VOLUME to BASS Use ARROWS to adjust accordingl...

Page 16: ...THERAPY to operate the pumps Press SOA K to operate Low Speed on pumps 1 and 2 Press JET 1 to operate high speed pump 1 Press JET 2 to operate high speed pump 2 Press JET 3 to operate high speed pump...

Page 17: ...N LOCK SPA FEHRENHEIT CELCIUS COUNTRY CODE Press SETUP to enter section Use UP and DOWN arrows to cycle past the selections Use the SELECT key to choose your selection then adjust accordingly Press BA...

Page 18: ...layed on main screen The name entered and all your own personal setting are saved on the system The set programming name setting will appear on screen in the WELCOME area The set programming name sett...

Page 19: ...will flash RUN SELF TEST will flash on your screen You then press MAINT to enter the maintenance mode you will have to be in Press STATUS to view status of pump setting amp draw and other settings St...

Page 20: ...Press MAINT to enter servicing section Press TEST to enter systems check Press BEGIN to start 4 00 minute countdown for testing Error Problem found will display ALL GOOD No problems found PAGE 14...

Page 21: ...outer rim of the jet s clockwise for minimum pressure and counter clockwise for maximum pressure Pressure may also be varied by the use of the air control This jet can be removed for cleaning by turni...

Page 22: ...rimary or secondary two speed pumps are operating Water may be diverted to two individual sections of jets or a combined operation of both sections Do not adjust when pump is set at high speed For the...

Page 23: ...ed I WATERFALL OPERATIONS On the Nuage and Romance model spas This valve increases or decreases volume of water from the waterfall On the Nuage a second valve of this type increases or decreases the v...

Page 24: ...nsert one of Vita Spa s exclusive aromatherapy scents and turn on the VitAroma Induction System The system is activated when the air blower button is depressed This system dispenses aromatherapy throu...

Page 25: ...ines shock with a chlorine or bromine shock EVERY 4 MONTHS Drain and refill spa Replace SPARKLE CLEAR cartridge AS NEEDED If water looks hazy shock treat with 1 teaspoon of dichlor per 250 gallons NOT...

Page 26: ...eaning while you continue to enjoy the use of your spa DRAINING YOUR SPA Detergent residues from bathing suits as well as soap film from your body may gradually accumulate in the water Foam inhibitors...

Page 27: ...ay or with any glass cleaner DO NOT clean the surface with any type of abrasive as it will dull the surface and natural luster of the acrylic DO NOT use any type of oil based solvent Such products can...

Page 28: ...filled or refilled a pump is operating but the water is not flowing from any of its jets This is a sign that the pump did not properly prime To correct please perform the following 1 Turn off the pow...

Page 29: ...esirable A two part bromine system or granular chlorine Dichlor are also acceptable sanitizers pH CONTROL pH is a measure of acidity and alkalinity of the spa water The recommended pH for spa water is...

Page 30: ...prevent calcium build up Calcium hardness 120 to 250 ppm Spray filter element to remove loose particles MONTHLY Four to six weeks Two to three months Inspect and clean the spa filter cartridge It is i...

Page 31: ...sits from staining the finish of your spa If your water is known to contain high concentrationsofthesemetalsit may benecessary to add an additional quantity of Spa Metal Inhibitor 3 Use a 3 Way Spa Wa...

Page 32: ...s sanitizer Check and adjust Chlorine level if Chlorine is used TOOALKA L INE SCALING ZONE COMFORTZONE TOO ACIDIC CORROSIVE ZONE ADD pH DECREASER TO LOWERpH IDEAL ADD pH INCREASER TO RAISE pH 8 4 8 2...

Page 33: ...issolves very slowly is highly concentrated and was designed for concrete or plaster swimming pools It will cause damage to your spa CHEMICAL SAFETY INSTRUCTIONS When using chemicals read labels caref...

Page 34: ...gent Overused or old water Excessive organics Body oils and dirt Inadequate filtration SOLUTIONS Clean filter with a filter cleaner or degreaser Shock the spa with POTASSIU M PEROXY MONOSULFATE Increa...

Page 35: ...Y MONOSULFATE maintain sanitizer at recommended level Raise pH with PH UP Shock with POTASSIUM PEROXY MONOSULFATE Maintain recommended sanitizer residual at all times super chlorinate Allow chlorine b...

Page 36: ...use 3 and then verify that the blower motor is plugged in Check that HEET pump is plugged in Check that current sensor board is plugged into circuit board Replace fuse 1 or fuse 2 Replace heater High...

Page 37: ...____________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________...

Page 38: ...___ _____________________________________________________ _____________________________________________________ _____________________________________________________ __________________________________...

Page 39: ......

Page 40: ...ES ALL RIGHTS RESERVED DM Industries Ltd 2320 Northwest 147th Street Miami Florida 33054 Phone 305 908 8187 Toll Free 877 240 9457 MIAMI FLORIDA Vita International Division of Is a Registered Trademar...

Reviews: