5
ENGLISH
–
When the set time is reached the unit will be
switched off.
–
To switch the timer off, press the button (15)
until the light indicators (16) go out.
Night illumination
The night illumination switches on automatically
when you switch the unit on, it is available in the
operating modes with low, medium and high mist
release intensity.
In normal operating mode the illumination colors
change by rotation.
Not enough water
–
When the water tank (2) and the process cham-
ber (8) become empty, the unit will switch off.
The illumination will light up red.
–
Unplug the unit and remove the water tank (2).
Fill the tank (2) with water (see chapter «Using
the air humidifier»). Install the water tank (2)
filled with water on the humidifier body (9).
–
Switch the unit on for further operation.
CLEANING AND CARE
WARNING!
Always switch the air humidifier off before clean-
ing, disconnect the power adapter (13) from the
mains and remove the adapter cord connector from
the socket (11). Hard water causes appearance of
mineral deposits (scale) in the process chamber
(8) and in the water tank (2) that leads to improper
operation of the unit. To avoid it:
–
use filtered and settled water. If tap water is
hard, it is recommended to mix tap water with
distilled water in proportion 1:1. If tap water is
too hard, mix it with distilled water in proportion
1:2 or use distilled water only.
–
Change water in the water tank (2) twice a week.
–
Thoroughly wash the process chamber (8) and
the water tank (2) with neutral detergent solu-
tion twice a week.
–
To clean the «sprayer» from the mineral deposit
(scale) (7) add 5-10 drops of detergent on it and
wait for approximately 10-15 minutes.
–
Remove the scale from the sprayer surface with
a soft brush, and then wash the process cham-
ber (8) with a neutral detergent solution.
–
Rinse the process chamber (8) several times.
Wipe the process chamber (8) with a soft cloth.
–
Clean the air humidifier body (9) with a soft,
slightly damp cloth, and then wipe it dry.
–
Clean the air inlet (4) and the air inlet grid (11)
on the unit body (9) bottom as it becomes
dirty.
–
To clean the float (5) remove it; to do this lift it
up and remove the left axis of the float from the
holder (6) groove, then remove the right axis.
Clean the float (5) from mineral scale.
–
Install the float (5) back to its place. To do it,
first insert the right axis of the float (5) into the
holder (6) opening and then insert the left axis
of the float (5) into the holder (6) groove. Make
sure that the float (5) axial movement (rotation)
is not hindered.
Notes:
–
do not immerse the air humidifier body into
water or other liquids;
–
do not use abrasives or solvents for cleaning the
sprayer (7);
–
you can use a descaling agent for kettles as a
detergent for the sprayer (7) and the float (5),
strictly following the instruction for this sub-
stance.
STORAGE
–
Pour the water out of the tank and make sure
that the process chamber and the sprayer are
dry before taking the unit away for storage.
–
Do not keep water inside the tank (2) or the pro-
cess chamber (8) of the unit.
–
Keep the air humidifier in a dry cool place away
from children and disabled persons.
TROUBLESHOOTING
Problem
Possible causes
Troubleshooting
No “mist”
The unit is connected
improperly
Check if the power plug is inserted into the mains socket.
The unit is off
Switch the unit on by pressing the button (13).
Water tank is empty
or there isn’t enough
water in the tank
Fill the water tank (2) with enough water.
IM VT-2346.indd 5
8/17/20 8:28 AM