5
ENGLISH
–
To stop the unit operation press the button
(12) again, the display (8) will go out.
–
Unplug the unit.
Notes:
The humidity level indications shown on the dis-
play (8) may be different from the readings of
another hygrometer.
The humidity level indications depend on the
room temperature.
Draughts or other air flows may affect the air
humidity indications in the room.
Control panel (9) and remote control (11)
buttons
Button (12)
Press this button to switch the
unit on and press it again to switch the unit off.
Button (13)
Press this button to switch the
ionization mode on, the mode indicator
will
light up on the display (8). To switch the ioniza-
tion mode off press the button again, the mode
indicator will go out.
Button (14)
Consequently press this button
to set the desired level of relative humidity in the
room within the range from 40% to 80% which
will be shown on the display (8), the indicator
will light up on the display (8). When the desired
relative humidity level is reached, the unit will be
switched off, when the relative humidity level
decreases, the unit will switch on. To switch the
selected humidity maintenance mode off press
the button (14) until the symbols «- - %» start
flashing on the display (8) and the indicator
goes out.
Button (15)
. After you press this button
the unit will start operating in the auto mode
with automatically maintained relative humid-
ity 55% - 68%, the mode indicator
will light
up on the display (8). To switch this mode off
press the button again, the mode indicator will
go out.
Button (16)
After you press this button,
the unit will switch to the “night” mode: the dis-
play (8) will go out, only the “night” mode indica-
tor
will be visible. To switch the “night” mode
off press any button, the display (8) will light up
and the indicator
will go out.
Button (17)
Consequently press this button
to select the mist release intensity:
«-» - low intensity,
«- -» - medium intensity,
«- - -» - high intensity.
Button (18)
. Consequently press this but-
ton to set up the timer within the range from 1 to
10 hours with 1 hour step which will be shown on
the display (8). The timer indicator will light up on
the display (8). When the set time is reached the
unit will be switched off. To switch the timer off
press the button (18) until the symbols «C» start
flashing on the display (8) and the indicator
goes out.
Low water level indication
When the water tank (4) becomes empty, the unit
will be switched off, you will hear a sound sig-
nal, and the red indicator
will light up red in
the upper right part of the display. Switch the unit
off with the button (12) and unplug it, remove the
nozzle (1) and the water tank (4). Fill the tank with
water (see the chapter «Using the air humidifier»).
Place the filled water tank (4) back to its place and
then install the nozzle (1). Switch the unit on.
CLEANING AND CARE
WARNING!
Always switch the unit off and
unplug it before cleaning.
Hard water causes appearance of mineral scale
in the process chamber (6) and in the water tank
(4) that leads to improper operation of the unit.
To avoid it:
–
use filtered, boiled and settled water. If tap
water is hard, it is recommended to mix tap
water with distilled water in proportion 1:1. If
tap water is too hard, mix it with distilled water
in proportion 1:2 or use distilled water only.
–
Change water in the water tank (4) twice a
week.
–
Thoroughly wash the process chamber (6)
and the water tank (4) with neutral detergent
solution twice a week.
–
To clean the «sprayer» add 5-10 drops of
detergent on it. Fill the process chamber (6)
with neutral detergent solution and wait for
approximately 10-15 minutes. Remove the
deposit from the «sprayer» surface with a soft
brush.
–
Rinse the process chamber (6) and the water
tank (4) twice. Wipe the process chamber (6)
with a soft cloth.
Notes:
Do not immerse the unit body into water or any
other liquids.
Do not use abrasives for cleaning the “sprayer”.
IM VT-2354.indd 5
29.04.2016 17:04:00
Summary of Contents for VT-2354 BK
Page 1: ...1 VT 2354 BK 3 8 13 18 23 Air humidifier IM VT 2354 indd 1 29 04 2016 17 03 59...
Page 2: ...IM VT 2354 indd 2 29 04 2016 17 03 59...
Page 14: ...14 www vitek ru 10 C 40 C 80 40 CR2025 IM VT 2354 indd 14 29 04 2016 17 04 01...
Page 19: ...19 www vitek ru 10 C 40 C 80 40 CR2025 IM VT 2354 indd 19 29 04 2016 17 04 02...
Page 24: ...24 www vitek ru 10 40 C 80 40 CR2025 IM VT 2354 indd 24 29 04 2016 17 04 03...