Cleaning of the cartridge filter
–
The cartridge filter prevents generation of
bacteria, softens water and removes unpleas-
ant smells.
–
Clean the cartridge filter every year after
passing of about 1000 l of water through it,
and if using hard water or a white deposit
appears on the furniture, more often.
–
Take the handle (3) and remove the water
tank (4) from the unit body. Remove the
nozzle (1).
–
Turn over the tank, remove the lid (5) with the
cartridge filter rotating it counterclockwise.
Remove the lid (5) from the cartridge filter.
–
Put the cartridge filter into a container filled
with 5% solution of non-iodized salt for 24
hours and then take it out and wash under
running water.
–
Install the cartridge filter back in the lid (5),
rotating it clockwise. Install the lid with the
cartridge filter back on the water tank (4).
Install the water tank (4) into the unit body.
TROUBLESHOOTING
Malfunction
Possible causes
Troubleshooting
No “mist”
The unit is connected improperly
Check if the power plug is inserted into the
mains socket.
The unit is off
Switch the unit on by pressing the button
(12).
Water tank is empty or there isn’t
enough water in the tank.
Fill the water tank with enough water.
Foreign smell
appears
during the
operation
First use
Disconnect the unit from the mains.
Remove the water tank, unscrew the lid (5)
and pour the water out of the water tank,
then leave the water tank in a dry cool place
for 12 hours.
Dirty or stale water
Unplug the unit, remove the water tank,
unscrew the lid (5), pour the water out
of the water tank and clean the tank (as
described in the chapter “Cleaning and
care”), then fill it with clean water.
Foreign noise
The water tank is installed
improperly.
Make sure that the water tank is installed
properly.
Not enough water in the tank
Fill the water tank with enough water.
The unit is placed on an uneven
surface.
Place the unit on a flat steady surface.
STORAGE
–
Pour the water out of the tank and make sure
that the process chamber and the «sprayer»
are dry before taking the unit away for storage.
–
Do not keep the unit with water inside the tank
or the process chamber.
–
Before taking the cartridge filter away for stor-
age, clean it and dry. Keep the cartridge filter
in a cool darkened place.
–
Keep the air humidifier away from children in
a dry cool place.
IM VT-2354.indd 6
29.04.2016 17:04:00
Summary of Contents for VT-2354 BK
Page 1: ...1 VT 2354 BK 3 8 13 18 23 Air humidifier IM VT 2354 indd 1 29 04 2016 17 03 59...
Page 2: ...IM VT 2354 indd 2 29 04 2016 17 03 59...
Page 14: ...14 www vitek ru 10 C 40 C 80 40 CR2025 IM VT 2354 indd 14 29 04 2016 17 04 01...
Page 19: ...19 www vitek ru 10 C 40 C 80 40 CR2025 IM VT 2354 indd 19 29 04 2016 17 04 02...
Page 24: ...24 www vitek ru 10 40 C 80 40 CR2025 IM VT 2354 indd 24 29 04 2016 17 04 03...