9
ENGLISH
–
dry the lid (8), protection screen (7) and sili-
cone gasket thoroughly;
–
place the silicone gasket on the protection
screen (7) and the protection screen (7) - on
the lid (8).
•
Wipe the surface of the heating element (only
when it is cold), do not allow water to get
inside the unit body.
•
Do not immerse the unit body, power cord
and plug into the water or other liquids.
•
Clean the multi-cooker body with a damp
cloth and then wipe dry.
•
Do not use abrasive and aggressive deter-
gents for washing of the unit and accessories.
•
Keep the multi-cooker away from children in
a dry cool place.
DELIVERY SET
Multi-cooker (with a lid) – 1 pc.
Bowl – 1 pc.
Soup ladle – 1 pc.
Spatula – 1 pc.
Measuring cup – 1 pc.
Instruction manual – 1 pc.
TECHNICAL SPECIFICTAIONS
Power supply: 220-240 V ~ 50/60Hz
Power: 1000-1190 W
Maximal capacity: 6 L
TROUBLES AND TROUBLESHOOTING
Failure
Possible Cause
Solution
The multi-cooker lid can’t
be closed.
The silicone gasket or pro-
tection screen (7) is installed
improperly.
Remove the protection screen, check
whether the silicone gasket is installed
properly.
The blocking system valve is
blocked in the upper position.
Remove the blocking object from the
valve.
The pressure in the multi-
cooker has been released,
but the lid can’t be opened.
The blocking system valve (11)
has not moved to the lower
position.
Press the valve on the lid handle and
set it down.
Steam is released from
the lid (8) bottom during
cooking.
The silicone gasket is not
installed on the protection
screen (7).
Switch the unit off, release the pres-
sure in the multi-cooker, open the
lid. Place the silicone gasket on the
protection screen (7).
The silicone gasket is very dirty. Clean the silicone gasket.
The silicone gasket is dam-
aged.
Replace the silicone gasket.
The lid (8) is not closed tightly. Close the lid (8) tightly.
Air release through the
blocking system valve (11).
The valve is dirty.
Switch off the multi-cooker, remove
the lid and and clean the valve.
The silicone ring of the blocking
system valve is damaged.
Replace the silicone ring of the valve.
The blocking system valve
(11) does not go up.
The pressure control valve (10)
is installed improperly.
Set the pressure control valve to the
position
.
Not enough ingredients or liq-
uid for steam generation.
Follow the recommendations for
amount of products and liquid in the
bowl (6).
Repeated sound signal.
The multi-cooker is overheated. Unplug the multi-cooker, open the lid
and let it cool down.
The manufacturer preserves the right to change the specifications of the unit without a preliminary
notification.