AIR WASHER  VT-8556

The  air  washer  traps  fine  dust  particles,  neu-

tralizes smoke odor, kills harmful bacteria, and 

the humidification function improves the indoor 

air quality.

DESCRIPTION

1.  Body (upper unit part)

2.  Outlet air grid

3.  Control panel 

4.  Water tank

5.  Inlet air grid 

6.  Carrying handle

7.  Water level scale

8.  HEPA filters

Control panel (3)

9.  Timer operation time selection  

button «

»

10. Timer operation time LED indicators 

«1Ч-2Ч-4Ч»

11.  On/off/speed selection button «

»

12. Operation speed LED indicators «I-II-III» 

DEFINING CHARACTERISTICS

Rooms such as a pantry, kitchen, office, cor-

ridor, toilet, usually have a closed air volume, 

which  contributes  to  the  growth  of  bacteria 

that are the source of unpleasant odors. The air 

washer resolves this problem and fills the room 

with  clean  air.  The  ionization  mode  generates 

anions and ozone (O

3

), which kills bacteria, and 

the HEPA filters unit traps the finest dust parti-

cles, pollen and fungus spores.

  Insufficient  room  humidity  negatively  affects 

the  health  of  humans,  pets,  plants  and  fur-

niture.  The  recommended  comfortable  room 

humidity level is from 40% to 60%. The humid-

ification  function  will  improve  the  indoor  air 

quality.

Attention! The air washer does not trap car-

bon monoxide (CO) or radon (Rn), so it cannot 

be used to filter the air in case of fire or danger-

ous chemical release.

Dear customer!

Please  read  this  instruction  manual  care-

fully  before  connecting  your  unit  to  the 

power supply to avoid damage due to mis-

use. Pay particular attention to the safety 

information.  If  you  transfer  your  unit  to 

a  third  party,  be  sure  to  hand  over  the 

instruction manual as well.

SAFETY INFORMATION

To  reduce  the  risk  of  injury,  fire  or  electric 

shock,  follow  the  basic  safety  precautions 

when  operating  the  unit,  including  the  fol-

lowing:

 •

Read the instructions carefully before use.

 •

Before  connecting  the  unit  to  the  power 

supply,  check  if  the  current  and  voltage  of 

the mains correspond to the operating volt-

age and current of the unit.

 •

Do not use the unit if the power cord or the 

power plug is damaged, if the unit operates 

intermittently or after it has been dropped.

 •

If  the  power  cord  is  damaged,  it  must  be 

replaced with a new one. 

 •

If the power cord is damaged, it should be 

replaced  by  the  manufacturer,  a  mainte-

nance service or similar qualified personnel 

to avoid danger.

 •

The unit and its parts, including the power 

cord,  must  in  no  case  be  repaired  by  the 

user. Otherwise the warranty is void.

 •

Do  not  repair  the  unit  by  yourself.  Do  not 

disassemble  the  unit  by  yourself,  in  case 

of  any  malfunctions,  as  well  as  after  the 

unit has been dropped, disconnect the unit 

from the mains and contact any authorized 

service  center  at  the  contact  addresses 

indicated  in  the  warranty  card  and  on  the 

website www.vitek.ru.

 •

If you find any damage during the warranty 

period,  please  contact  the  retailer  from 

whom you purchased the product. After the 

warranty expires, contact a service techni-

cian or certified technician.

 •

Do not leave the switched on unit unattended.

 •

Do  not  let  the  power  cord  hang  from  the 

sharp edges of any objects or furniture.

 •

Do  not  place  the  unit  near  heating  appli-

ances, electric or gas stoves.

 •

When using a gas stove at home, it is rec-

ommended to use distilled water for the air 

washer.

 •

Keep the unit out of direct sunlight.

 •

Do not use the unit in an environment, where 

the relative room humidity exceeds 80%. In 

a high humidity environment, where the rela-

tive humidity is above 60%, use the unit only 

when necessary and only with the unit set to 

the lowest humidification level.

Attention!  Mishandling  the  unit  may  cause 

injuries.

 •

Do  not  use  the  unit  in  a  room  with  a  high 

humidity level, such as a bathroom.

 •

Do not use the unit in explosive and/or flam-

mable  atmospheres,  where  aerosols  are 

sprayed or flammable liquids are used.

 •

Do  not  cover  the  air  grids  or  insert  any 

objects into them.

IM VT-8556.indd   3

8/25/20   3:18 PM

Summary of Contents for VT-8556

Page 1: ...1 VT 8556 3 7 12 17 22 Air Washer IM VT 8556 indd 1 8 25 20 3 18 PM...

Page 2: ...1 5 6 7 4 3 5 8 8 2 9 10 11 12 IM VT 8556 indd 2 8 25 20 3 18 PM...

Page 3: ...ing the unit to the power supply check if the current and voltage of the mains correspond to the operating volt age and current of the unit Do not use the unit if the power cord or the power plug is d...

Page 4: ...entilation openings people walls furniture wooden floors sockets or other electrical devices Do not place the unit on unprotected furni ture wooden floors etc Use for example a waterproof material to...

Page 5: ...sponds to a 4 hour timer operation Humidity level setting By successively pressing the button 11 set the required operation speed the LED indica tor 12 of the corresponding speed will light up I corre...

Page 6: ...y 220 240 V 50 60 Hz Rated input power 25 W Tank capacity 2 L Water discharge 120 150 ml h Ozone output less than 0 05 ppm Area serviced up to 25 m2 RECYCLING For environment protection do not throw o...

Page 7: ...7 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III O3 HEPA 40 60 Rn www vitek ru IM VT 8556 indd 7 8 25 20 3 18 PM...

Page 8: ...8 80 60 IM VT 8556 indd 8 8 25 20 3 18 PM...

Page 9: ...9 50 60 1 HEPA 8 4 HEPA 8 HEPA 1 4 10 C 40 C 80 40 1 HEPA 8 4 HEPA 8 4 1 4 11 11 12 9 10 1 1 IM VT 8556 indd 9 8 25 20 3 18 PM...

Page 10: ...10 2 2 4 4 11 12 I II III 11 III 2 HEPA HEPA 11 IM VT 8556 indd 10 8 25 20 3 18 PM...

Page 11: ...240 50 60 25 2 120 150 0 05 25 2 info vitek ru 3 STAR PLUS LIMITED 15 38 117452 17 1 4 401 1 7 499 685 48 18 E MAIL info vitek ru 117452 17 1 4 401 1 www vitek ru 8 800 100 18 30 IM VT 8556 indd 11 8...

Page 12: ...12 VT 8556 1 2 3 4 5 6 7 8 3 9 10 1 2 4 11 12 I II III O3 40 60 Rn www vitek ru IM VT 8556 indd 12 8 25 20 3 18 PM...

Page 13: ...13 80 60 IM VT 8556 indd 13 8 25 20 3 18 PM...

Page 14: ...14 50 60 1 8 4 8 1 4 10 C 40 C 80 40 1 8 4 8 4 1 4 11 11 IM VT 8556 indd 14 8 25 20 3 18 PM...

Page 15: ...15 12 9 10 1 1 2 2 4 4 11 12 I II III 11 III 2 11 IM VT 8556 indd 15 8 25 20 3 18 PM...

Page 16: ...16 12 1 1 220 240 50 60 25 2 120 150 0 05 25 info vitek ru 3 i i i i i i i i i i i i IM VT 8556 indd 16 8 25 20 3 18 PM...

Page 17: ...17 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III 3 HEPA 40 60 Rn www vitek ru IM VT 8556 indd 17 8 25 20 3 18 PM...

Page 18: ...18 80 60 IM VT 8556 indd 18 8 25 20 3 18 PM...

Page 19: ...19 50 60 1 HEPA 8 4 HEPA 8 HEPA 1 4 10 C 40 C 80 40 1 HEPA 8 4 HEPA 8 4 1 4 11 11 12 9 IM VT 8556 indd 19 8 25 20 3 18 PM...

Page 20: ...20 10 1 1 2 2 4 4 11 12 I II III 11 III 2 HEPA HEPA 11 IM VT 8556 indd 20 8 25 20 3 18 PM...

Page 21: ...21 12 1 1 220 240 50 60 25 2 120 150 0 05 25 2 info vitek ru 3 2014 30 2014 35 IM VT 8556 indd 21 8 25 20 3 18 PM...

Page 22: ...22 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III O3 40 60 Rn www vitek ru IM VT 8556 indd 22 8 25 20 3 18 PM...

Page 23: ...23 80 60 IM VT 8556 indd 23 8 25 20 3 18 PM...

Page 24: ...24 50 60 50 60 1 8 4 8 1 4 10 C 40 C 80 40 1 8 4 8 4 1 4 11 11 12 9 IM VT 8556 indd 24 8 25 20 3 18 PM...

Page 25: ...25 10 1 1 2 2 4 4 11 12 I II III 11 III 2 11 IM VT 8556 indd 25 8 25 20 3 18 PM...

Page 26: ...26 12 1 1 220 240 50 60 25 2 120 150 0 05 25 info vitek ru 3 IM VT 8556 indd 26 8 25 20 3 18 PM...

Page 27: ...IM VT 8556 indd 27 8 25 20 3 18 PM...

Page 28: ...late A serial number is an eleven unit number with the first four figures indicating the production date For example serial number 0606 means that the item was manufactured in June the sixth month 200...

Reviews: