5
ENGLISH
Warning! Before filling the tank with water,
switch the unit off and unplug it. Be careful not
to get the unit body wet.
Note: Use the unit at the room temperature
between +10°C and +40°C and the relative
humidity less than 80%. The used water tem-
perature should not be higher than +40°С.
USING THE AIR WASHER
–
Place the unit on a solid, flat and stable sur-
face.
–
Remove the air outlet grid (1).
–
Fill the water tank (4) with water up to the
maximal level (9) (MAX) using a suitable
bowl. Always use clean, cold tap water. Since
water quality varies by region, it is recom-
mended to use distilled or filtered water to
minimize the risk of contamination and calci-
fication (scale formation).
Warning! To ensure proper operation of the
unit, do not exceed the maximal level mark (9).
–
Insert the plug into the mains socket, all sym-
bols on the control panel will light up, you will
hear a short sound signal and the unit will
switch to the standby mode. The on/off but-
ton (12) «
» in the standby mode will will be
dimmed to half the brightness level.
Note:
–
the operation mode control buttons on the
control panel are sensory, you just need to
touch the button to switch the necessary
operation mode on.
–
in the active mode the operation mode con-
trol buttons (10) «
», (11) «
», (15) «
»
are dimmed.
–
when you press a control button in the active
mode, its brightness increases to maximum.
Switching the unit on and off
–
To switch the unit on press and hold the on/
off button (12) «
» for more than 1 sec-
ond. You will hear a sound signal, the current
humidity level will appear on the display (14).
The on/off button (12) «
» brightness will
be maximal, and the operation mode control
buttons (10) «
», (11) «
», (15) «
» will be
active and dim.
Note:
–
If operation mode control buttons are not
pressed within 10 seconds, the on/off button
(12)«
» will be dimmed to half the bright-
ness, and other control buttons will go out
and will be locked.
–
To unlock the control buttons, touch the
dimmed on/off button (12) «
», other con-
trol buttons will be unlocked and dimmed.
When you press any button, its brightness will
increase to maximum.
–
To switch the unit off, press and hold the on/
off button (12) «
» for more than 1 second,
you will hear a short sound signal, all symbols
on the control panel will go out and the unit
will switch to the standby mode. The on/off
button (12) «
» in the standby mode will will
be dimmed to half the brightness level.
Water level indication (13)
The level indicator consists of four lines, each
line corresponds to a certain water level.
–
When there is not enough water in the water
tank (4) or when it is empty, all four indicator
(13) lines flash red.
–
As the water tank is filled with clean water, all
four indicator (13) lines consequently appear,
and the indicator color changes to white.
–
When the water reaches a sufficient level
(when the tank is full), you will hear three
beeps and the indicator will be flashing for
3 seconds.
Humidity level adjustment
–
When you switch the unit on from the standby
mode or the sleep mode, the unit sets the
automatic humidification mode, and the auto-
matic mode indicator (18) «A» lights up on
the control panel. The automatic humidifica-
tion mode maintains a comfortable relative
humidity level in the room.
–
You can set two humidification levels with the
humidity level control button (15) «
».
–
To change the humidity level, first press the
on/off button (12) «
», the humidity level
control button (15) «
» will become active
and dimmed.
–
Consequently press the button (17) «
» to
select the required level. The LED indicators
(17, 18) of the corresponding levels will con-
sequently light up on the control panel: «
» -
level 1, «
» - level 2, «A» - automatic mode
Sleep mode
In the sleep mode the unit is quiet and there is
no light indication on the control panel, and the
automatic humidification mode is switched on.
–
To switch the sleep mode on, first press the
on/off button (12) «
», the sleep mode
button (11) «
» will become active and
dimmed.
–
Press the button (11) «
», and the unit will
switch to the sleep mode. All indicators on the
control panel will go out, and the button (11)
«
» brightness will be maximal. After 10 sec-
IM VT-8557.indd 5
10/27/20 2:46 PM
Summary of Contents for VT-8557
Page 1: ...1 VT 8557 3 8 14 20 26 Air Washer IM VT 8557 indd 1 10 27 20 2 46 PM...
Page 2: ...1 10 12 11 15 16 14 17 18 13 2 3 4 7 6 8 5 9 IM VT 8557 indd 2 10 27 20 2 46 PM...
Page 9: ...9 80 60 IM VT 8557 indd 9 10 27 20 2 46 PM...
Page 10: ...10 50 60 10 C 40 C 80 40 1 4 9 MAX 9 12 10 11 15 12 1 14 IM VT 8557 indd 10 10 27 20 2 46 PM...
Page 12: ...12 1 2 2 3 4 2 30 IM VT 8557 indd 12 10 27 20 2 46 PM...
Page 15: ...15 80 60 IM VT 8557 indd 15 10 27 20 2 46 PM...
Page 18: ...18 1 2 2 4 3 2 30 1 1 220 240 50 60 18 4 300 30 2 33 IM VT 8557 indd 18 10 27 20 2 46 PM...
Page 19: ...19 info vitek ru 3 i i i i i i i i i i i i IM VT 8557 indd 19 10 27 20 2 46 PM...
Page 21: ...21 80 60 IM VT 8557 indd 21 10 27 20 2 46 PM...
Page 24: ...24 10 3 1 2 2 3 4 2 30 IM VT 8557 indd 24 10 27 20 2 46 PM...
Page 27: ...27 80 60 IM VT 8557 indd 27 10 27 20 2 46 PM...
Page 30: ...30 1 2 2 3 4 2 30 IM VT 8557 indd 30 10 27 20 2 46 PM...
Page 31: ...31 1 1 220 240 50 60 18 4 300 30 2 33 info vitek ru 3 IM VT 8557 indd 31 10 27 20 2 46 PM...