background image

18

EN

2. GENERAL USE & 

SAFETY WARNINGS

While using agricultural 

equipment, several basic 

safety precautions must always be 

followed in order to reduce the risk 

of fire, electric shock and personal 

injuries.

 

Read and understand the 

manual prior to operating this 

tiller. Save these instructions and 

other documents supplied with this 

machine for future reference.

2.1 - GENERAL

These preventive measures are 

essential for your safety. Always use the 

compressor with care in a responsible 

manner having in consideration that 

its user is responsible for eventual 

accidents caused to third parties or 

their goods.

Make sure that all individuals using the 

compressor for the first time have had 

the necessary training and have read 

and fully understand these operating 

instructions.

This instruction manual is an integral 

part of the compressor and must 

always be provided. 

Get familiar with the equipment’s 

control devices and operation. The user 

must know how to stop the compressor 

immediately.

Stay focus and use common sense 

while operating the compressor. A 

moment of inattention may result in 

serious injuries. 

Use this compressor only if you are in 

good physical and mental conditions. 

Do not use this equipment if you are 

tired or under the influence of alcohol, 

drugs or medication. If you suffer from 

any health problem, please ask your 

doctor about the possibility of using the 

compressor.

Never allow the compressor to 

be used by children, people with 

limited physical, sensorial or mental 

capabilities, with lack of experience 

and knowledge of this equipment and 

who is not familiar with the instructions. 

This compressor must only be 

operated as described in this 

instruction manual. No other use is 

allowed besides the described.

Do not overload the compressor. Any 

equipment has a greater performance 

and safety when operated under the 

power limits indicated in the technical 

specifications. 

Use the compressor properly and 

according each type of work.  Using 

this equipment for purposes other than 

the intended may result in dangerous 

situations.

For safety reasons, any changes other 

than the assembly of accessories 

authorized by the manufacturer are 

prohibited. Any changes made void the 

warranty. 

This compressor is not suitable for 

commercial use. The warranty is void 

in case of commercial use.

You can obtain any information about 

the authorized accessories through 

your VITO official distributor.

2.2 - ELECTRICAL SAFETY

Do not use this compressor in an 

explosive environment, especially in the 

presence of flammable liquids, gases 

or dusts. Any power tool may form 

sparks that might ignite liquids, gases, 

or dust.

Do not expose any power tools 

to rain or use them in wet or 

damp environments. The presence of 

water in an electric tool increases the 

risk of damage and electric shock to the 

user.

The supply voltage must match 

the compressor’s technical 

specifications. Keep voltage between 

+- 5% of nominal value. Do not use the 

equipment where the power supply isn’t 

stable. 

The power cable must be plugged into 

an electrical outlet with a differential 

protection and earth connection. If the 

working area is extremely hot, damp or 

with high dust concentration, the power 

outlet circuit must be protected with a 

circuit breaker (30mA), to ensure the 

user’s safety.

Never use the power cable to pull, 

carry or unplug the tool. Damaged 

power cables increase the risk of 

electric shock.

Keep the power cable and plug away 

from heat sources, oil, sharp objects 

and the rotating accessory. If the power 

cable is damaged, it must be replaced 

by a qualified technician; it is not 

allowed to repair it.

Do not modify the power cable plug.  

Use a compatible socket with the plug 

of this compressor. Do not use any type 

of adapter.

The use of extension cords to connect 

the power cable is not recommended. 

However, if you use an extension, you 

SYMBOLOGY

Safety warnings and 

precautions.
All users must read the 

instruction manual to 

avoid injuries.

Risk of electric shock.

Danger of fire or 

explosion.
Respect the safety 

distance.
Recycled material 

packaging.
Separate collection of 

batteries and / or power 

tools.

Summary of Contents for AUTO VICO230V

Page 1: ...TRUCCIONES INSTRUCTION MANUAL MODE D EMPLOI MINI COMPRESSOR PORT TIL 230V 140W MINI COMPRESOR PORTATIL 230V 140W PT ES MINI PORTABLE COMPRESSOR 230V 140W MINI COMPRESSEUR PORTATIF 230V 140W EN FR P g...

Page 2: ...n Fr quence Pot ncia Potencia Rated Input Puissance Press o Presi n Pressure Pression Fluxo de ar Flujo de aire Air flow D bit d air Certifica o Certificaci n Certified Certification ICONOGRAFIA ICONO...

Page 3: ...E CONTE DO DA EMBALAGEM ES DESCRIPCI N DE LA HERRAMIENTA Y CONTENIDO DEL EMBALAJE EN PRODUCT SPECIFICATION AND BOX CONTENT FR DESCRIPTION DE L APPAREIL ET DU CONTENU DE L EMBALLAGE 3 Fig B Fig A 2 3...

Page 4: ...4 Fig D Fig E 3 2 1 2 Fig C 2 3 4 1 5 1...

Page 5: ...DO MEIO AMBIENTE 9 7 APOIO AO CLIENTE 9 8 PERGUNTAS FREQUENTES RESOLU O DE PROBLEMAS 10 9 CERTIFICADO DE GARANTIA 10 10 DECLARA O DE CONFORMIDADE 10 NDICE LISTA DE COMPONENTES 1 Interruptor de ligar d...

Page 6: ...por crian as pessoas com capacidades f sicas sensoriais ou mentais limitadas pessoas com falta de experi ncia e conhecimento do equipamento ou outras pessoas que n o estejam familiarizadas com as inst...

Page 7: ...e involunt rio do compressor Nunca utilize equipamentos em que n o seja poss vel ligar e desligar o interruptor Verifique se os dispositivos de seguran aest oemperfeitascondi es e se funcionam correta...

Page 8: ...rios de insufla o fornecidos Liga o com a v lvula de liga o 1 Enrosque a v lvula de liga o 7 do compressor na v lvula do objeto a insuflar por ex pneu Liga o com acess rio de insufla o 2 Enrosque o a...

Page 9: ...svazieoreservat riodearcomprimido e deixe arrefecer o compressor de forma a evitar eventuais acionamentos acidentais e queimaduras 5 1 SUBSTITUI O DO DISPOSITIVO DE SEGURAN A CONTRA SOBRECARGA FUS VEL...

Page 10: ...1 2013 IEC 62321 5 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 e IEC 62321 6 2015 conforme as determina es das diretivas Diretiva 2014 30 EU Directiva...

Page 11: ...5 6 PROTECCI N DEL MEDIO AMBIENTE 15 7 APOYO AL CLIENTE 15 8 PREGUNTAS FRECUENTES RESOLUCI N DE PROBLEMAS 16 9 CERTIFICADO DE GARANT A 16 10 DECLARACI N DE CONFORMIDAD 16 LISTADO DE COMPONENTES 1 Inte...

Page 12: ...nte debe ser utilizado como detallado en esto manual No son permitidas otras utilizaciones que puedan ser peligrosas y que provoquen lesiones al utilizador o al equipo No sobrecargue el compresor y ut...

Page 13: ...ello debe ser reparado o sustituido para evitar el arranque involuntario de la m quina Nunca utilice equipos en los cuales no es posible encender o apagar el interruptor Comprobar si los dispositivos...

Page 14: ...ar por ex neum tico Conexi n con accesorio de insuflaci n 2 Enganche el accesorio de insuflaci n 8 seg n el objeto a insuflar 3 Introduzca el accesorio de insuflaci n en la v lvula del objeto a insufl...

Page 15: ...modo a evitarse eventuales arranques accidentales y quemaduras 5 1 CAMBIO DE LOS DISPOSITIVOS DE SEGURIDAD CONTRA LA SOBRECARGA FUSIBLE FIG E En el caso de sobrecarga o de mal funcionamiento el fusibl...

Page 16: ...C 62321 1 2013 IEC 62321 3 1 2013 IEC 62321 5 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 e IEC 62321 6 2015 de acuerdo con las determinaciones de las...

Page 17: ...5 2 Cleaning and storage 21 6 ENVIRONMENT SAFETY 21 7 CUSTOMER SERVICE 21 8 FREQUENTLY ASKED QUESTIONS TROUBLESHOOTING 22 9 WARRANTY 22 10 DECLARATION OF CONFORMITY 22 COMPONENTS LIST 1 ON OFF switch...

Page 18: ...ype of work Using this equipment for purposes other than the intended may result in dangerous situations For safety reasons any changes other than the assembly of accessories authorized by the manufac...

Page 19: ...ildren are nearby Keep the working area clean organized and well illuminated brightness from 250 to 300 lux in order to reduce the risk of accidents The control and safety devices installed in the mac...

Page 20: ...ssor The pipes or hoses coupled to the compressor must have flow and pressure characteristics similar to the technical specifications of the compressor The compressor must only be operated in environm...

Page 21: ...d extends its lifespan Keep the machine and its ventilation openings unobstructed Clean them regularly to avoid clogs Storage When the hammer isn t being used it shall be kept inside a dry place corro...

Page 22: ...IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 and IEC 62321 6 2015 according to the determinations of the directives 2014 30 EU Electromagnetic compatibility...

Page 23: ...ttoyage et rangement 27 6 PROTECTION DE L ENVIRONNEMENT 27 7 SERVICE CLIENT 28 8 QUESTIONS FR QUENTES R SOLUTION DES PROBL MES 28 9 CERTIFICAT DE GARANTIE 28 10 DECLARATION DE CONFORMIT 28 INDICE COMP...

Page 24: ...et appareil doit tre exclusivement utilis conform ment ce qui est d crit dans ce manuel d instructions Aucune autre utilisation n est autoris e car cela pourrait tre dangereux et pourrait causer des b...

Page 25: ...res N utilisez jamais de pi ces ou d accessoires endommag s Assurez vous que l interrupteur est teint lorsque vous connectez le c ble d alimentation Si le bouton est endommag ou s il ne permet pas de...

Page 26: ...S ACCESSOIRES D INSUFFLATION FIG B Selon le type d objet insuffler l utilisateur peut utiliser la valve de connexion directement dans l objet ou avec les accessoires d insufflation fournis Liaison ave...

Page 27: ...te op ration de manutention ou de nettoyage d branchez le c ble d alimentation de la prise de courant videz la cuve d air comprim et laissez le compresseur refroidir pour viter d ventuels d marrages a...

Page 28: ...2321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 et IEC 62321 6 2015 selon les d terminations des directives 2014 30 UE Directive sur la compatibilit lectromagn tique 2011 65 UE Directive ROHS S Jo o...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...RUA DA G NDARA 664 4520 606 S JO O DE VER STA MARIA DA FEIRA PORTUGAL MI_VICO230V_REV00_MAR18...

Reviews: