2000I & 2000M Instrument’s User Guide, Revision B
36
Note that the units for this data are automatically those previously selected for
the Output A data.
9.
The display then prompts you to enter User Data B and displays the presently
stored data. Press any units key (if this data is to be retained) or enter the de-
sired data and then press any units key. Note that the units for this data are au-
tomatically those previously selected for the User Data A data.
10.
Following entry of the above data, the instrument will then initiate the “Cal-
culated Output” mode of operation.
Operating in the Calculated Output Mode
Operation of the instrument while in the “Calculated Output” mode of operation
is the same as that while in the normal mode of operation, with the following
exceptions:
1.
Numeric entries of the required output level are in the user units set during
the set-up of this mode of operation, thus the unit key used to terminate the
entry is discarded.
2.
While a multiplier key may be used during the entry, this does not affect the
display format (it is used to scale the entered data however).
3.
The “Adjust” mode may be used while in “Calculated Output”
mode; howev-
er, the display format is such that the user units are not displayed during the
adjustment process.
4.
The data points A and B may be changed while in “Calculated Output”
mode
by simply repeating the procedure as was used to initiate this mode. The new
factors replacing those previously used. Note that these data are stored in a
non-volatile manner, thus are available always, even following power-down.
Deselecting the Calculated Output Mode
Deselecting the “Calculated Output” mode of operation is achieved by pressing
any of the Units/Enter keys (V, A, ºC or ºF
)
without prior numeric entry. This
action will deselect the “Calculated Output”
mode of operation and leave the out-
put level and type unaffected. The display will show the output level correspond-
ing to the previously used user data. This deselecting process may be used as a
check of the entered data.
Summary of Contents for Xitron 2000 Series
Page 1: ...USER GUIDE 2000 Family DC Temperature Source Instruments...
Page 2: ......
Page 18: ...2000I 2000M Instrument s User Guide Revision B 18...
Page 42: ...2000I 2000M Instrument s User Guide Revision B 42...
Page 47: ...Using the Memory Options 47...
Page 60: ...2000I 2000M Instrument s User Guide Revision B 60...
Page 91: ......
Page 92: ...2000I 2000M Instrument s User Guide Revision B 92...
Page 95: ...Appendix B General Specifications 95...
Page 97: ...Password Page 97...