Sending Commands to the 2553/ 2553E
35
WAVEFORMS /
pp
/ CONT-VA /
xx
/
tt
WAVEFORMS /
pp
/ CONT-VW /
xx
/
tt
pp = the phase for which the data is to be printed, one of the following ASCII strings :
A, B, C, or TOTAL. Note that TOTAL is available in PCL only.
xx = the desired zoom factor, one of the following ASCII strings : x0.5 x1 x2 x5
tt = the characters TEXT or PCL dependant on the printout format desired
Table 21 – Data for the PRINT command, Waveforms format
HISTORY /
pp
/ V-RMS /
tt
HISTORY /
pp
/ V-PEAK /
tt
HISTORY /
pp
/ V-THD /
tt
HISTORY /
pp
/ A-RMS /
tt
HISTORY /
pp
/ A-PEAK /
tt
HISTORY /
pp
/ A-THD /
tt
HISTORY /
pp
/ WATTS /
tt
HISTORY /
pp
/ VAR /
tt
HISTORY /
pp
/ PF /
tt
pp = the phase for which the data is to be printed, one of the following ASCII strings: A,
B, C, or TOTAL
tt = the characters TEXT or PCL dependant on the printout format desired
Table 22 – Data for the PRINT command, History format
Examples –
•
The user transmits: PRINT=BASIC/TOTAL<NL>
The 2553/ 2553E initiates printing of a single-page tabulation of measured, inrush,
integrated and integrated average results over all phases. Voltage and current RMS
will be the mean phase data, power will be the overall total.
•
The user transmits: PRINT=HARMONIC-LIST/A<NL>
The 2553/ 2553E initiates printing of a single-page tabulation of measured voltage
and current harmonics for phase A, giving results in absolute units, percentage of
fundamental, and phase relative to voltage fundamental.
•
The user transmits:
PRINT=HARMONIC-BARCHART/B/ABS-LOG/VOLTAGE/PCL<NL>
The 2553/ 2553E initiates printing of a single-page graphical representation of a
voltage harmonic barchart for phase B, using absolute units with a logarithmic scale.
Assumption: The printer supports PCL level 2 graphics with a minimum of 75dpi
raster graphics capability.
Summary of Contents for Xitron 2553
Page 1: ...IEEE488 COMMAND GUIDE 2553 2553E Three Phase Power Analyser ...
Page 2: ......
Page 10: ...10 2553 2553E Command Guide ...
Page 38: ...38 2553 2553E Command Guide ...