EN
EN
11.1
THE APPLIANCE DOES NOT WORK
Check that:
−
it is energised.
−
the "STAND-BY" switch D1 is active and the LED is on.
−
the automatic circuit breaker of the electrical system is not disconnected.
−
the plug is efficient and correctly inserted into the socket and the power
outlet works. For this verification, connect to the socket a device whose
functioning is certain.
−
the supply cable is not interrupted.
11.2
NOISY ICE MAKER
Check that:
−
the ice maker is on a level surface.
−
the ice maker is not in contact with furniture that can could cause vibrations.
−
the refrigerant circuit pipes located on the back have no contact points and
do not vibrate against the appliance.
11.3
ICE MAKER WITH INSUFFICIENT PRODUCTION
Check that:
−
the door closes hermetically.
−
the ice maker is not near heat sources.
−
the ice maker is sufficiently ventilated.
−
the condenser is not clogged with dust.
−
the fan turns freely.
11.4
THE ICE MAKER DOES NOT MAKE ICE
Check that:
−
the refrigeration system is in operation and produces cold.
−
there is water in the ice cube tray (A).
−
the water system is efficient.
−
there is sufficient water in the tank (Refill version)
−
keys D1 and D2 are active
−
the internal temperature in the cell is approximately ≤
-15°C.
−
the ice level sensor (B) is in the position shown in fig.4
−
if there is water in the ice cube tray, check the functionality of the
refrigerant system (H).
−
there is no cube stuck in the ice cube tray.
11.5
THE ICE MAKER DOES NOT DISPENSE ICE
Check that:
−
there is ice in the ice cube tray.
If there is, reset the system by switching it off for ~4/5 hours.
If you do not manage to achieve regular operation after these checks,
contact the customer assistance service.