− The minimum power mode (see paragraph “4.3. Using your
conditioner”) has not been selected.
− The condenser is not clogged by dust.
− The fans can turn freely.
− There are no error or alarm signals ongoing (see paragraph “4.5.
ALARM / ERROR Signal”).
− The difference in temperature between incoming and outgoing air at
the openings is between 8 and 10°C
If, after making these checks, your conditioner still does not operate correctly,
contact the assistance service.
8. PANEL MALFUNCTION SIGNALS
When the “
Alarm/error
” indicator light switches on, this means that there is
an operating malfunction caused by a failure or by the occurrence of a critical
situation.
The indicator light switching on is accompanied by an error code on the display
(an E followed by a number, e.g. E.001) or by an alarm code (an A followed by
a number, e.g. A.064). See the table below for instructions concerning the code
number displayed.
8.1. ERROR SIGNALS
The value on the display (3) shows the malfunction found. Carry out the
appropriate operations according to the problem being signalled (see the
table below).
Error
Error type
Intervention
E001 Cab tilt
protection
stoppage
signal
The conditioner has been stopped following the
detection of the tilted cab.
The signal continues for 20 minutes from when the cab
returns to the normal position
If this error persists, even after 20 minutes with the
cab is in the normal position, contact the assistance
service.
E002 Cab interior
temperature
probe
anomaly
signal
A temperature value anomaly is signalled. If the
temperature inside the cab is above 60°C or lower than
4°C, take the temperature to within these values.
If the problem persists, contact the assistance service.