Moster 185 Factory R - Maintenance manual - V1
111
3.13.2 Crankcase maintenance
Degrease the bearing seats, the profile of the case-half and the crankcase support with specific
products for aluminium.
Check the case-half: check for integrity and abnormal marks.
Check the 2 bearing seats: there must be no polished areas. Also measure the diameter of the 2
seats, the table shows the factory settings.
Dimension
Factory settings at 20° C
(mm)
1
46,960-46,980
2
46,960-46,980