4. operation & service
Mains fuses
The mains fuses are accessible
from the outside of the
amplifier . You will find the
mains fuses just below the
power inlet . If the fuses blow,
then you can easily replace
them . The fuses only blow
on the occurrence of power
surges or if there is a fault
in the unit . Normally power
surges cause no other damage
other than blowing the
fuses . When the fuses blow
repeatedly on replacement,
then the unit most likely has
a malfunction . In case of
malfunction the unit must be
returned to Vitus Audio for
repair .
Fuse type:
230V
: 20 x 5mm – 2 A – T -
LBC fuse (Time lag fuse)
115V
: 20 x 5mm – 4 A – T -
LBC fuse (Time lag fuse)
100V
: 20 x 5mm – 4 A – T -
LBC fuse (Time lag fuse)
Replacing the fuses with fuses of a type
and rating different from the original
fuses, might result in damage to the unit
and injury to you (the user) . Damage to
the unit as a result of wrongly replacing
the mains fuse, will invalidate the
guarantee .
For an explanation of how to replace the
fuse see “Replacing a blown fuse”chapter 4 .
4 .
operation &
service
Summary of Contents for MP-L201
Page 1: ...MP L201 Owner s Manual ...
Page 47: ...47 MP L201 Version 1 7 examples connecting devices 7 examples Connecting devices ...
Page 48: ...48 MP L201 Version 1 7 examples connecting devices Connecting devices ...
Page 76: ...76 MP L201 Version 1 9 pictures MP L201 Inside view MP L201 Inside view ...
Page 77: ...77 MP L201 Version 1 9 pictures MP PSU Inside view MP PSU Inside view 9 pictures ...
Page 78: ...78 MP L201 Version 1 9 pictures MP L201 Front MP L201 Front view ...
Page 79: ...79 MP L201 Version 1 9 pictures 9 pictures RC 010 Front RC 010 Front view ...