Page 8 of 67
2 vLoc3 RTK-Pro Receiver
2.4.18 Cloud
Enter this option to check the Cloud connection status. In order to use the Cloud-based VMMAP data logging facility, an account needs
to be set up and each locator needs to be registered with the Vivax-Metrotech VMMap mapping application. For further information on
this contact Vivax-Metrotech Corp. This User Guide assumes the locator is registered and the operator has an active account.
2.4.19 GPS RTK Source
Enter this option to check RTK connectivity and to select RTK source. For further information check the section Setting up RTK
Connectivity.
2.4.20 New Survey
Entering the Survey sub-menu causes a new survey to be initiated in the SD Card Data Logger
DM Graphs are cleared so that a new survey is identifiable from older measurements.
Different Survey types can be selected as shown
Navigating into this menu and selecting a survey type always causes a new survey to be initiated, even if it is the same type as
the previous log record.
Electric
Gas
Communications
Potable Water
Reclaimed Water
Sewer
Temporary Survey
Proposed Excavation
Oil
2.4.21 Regulatory Labels
Enter this option to display all relevant FCC and IC regulatory labels.
2.4.22 Self-Test
Pressing the enter key will initiate a series of self-tests. If any of the tests fail, repeat the test in a more interference-free site
i.e. away from fluorescent lights, power signal sources etc. If the unit continues to fail, the unit should be returned to Vivax-
Metrotech Corporation or one of its authorized service centers for repair.
2.5 Self-Test
The vLoc3 RTK-Pro has a self-test feature. The test confirms that the equipment is fit for use and calibration has not drifted from
its expected settings.
To undertake the test, first find an area free from excessive interference such as overhead fluorescent lighting, large
transformers etc. Also check that any nearby vLoc transmitters are switched off.
Select “Self-Test” from the user menu and press the “Return” button. The test will self-start. Keep the equipment stationary while
the test is completed. After a short while the unit will report a Passed or Failed. Examples are below:
108.1
63.1
88.6
87.0
Self Test: PASSED
108.1
63.1
88.6
87.0
Self Test: FAILED
If the unit fails the test, try again in a more interference-free area. If it continues to fail, return the unit to Vivax-Metrotech or one
of its approved repair centers for investigation and repair.